6

Technical data extract

Temperature range

–20...+130 °C, 140 °C < 60 min.

Operating pressure

max. 10 bar

Inputs

2 x 24-V control input (pnp); 18 V ... 36 V

Outputs

2 x 4...20 mA active galv. sep.; load max. 500 Ohm

Repeatability, cond.

< ±1% of full-scale range

Accuracy, temp.

< ±0.2 °C (0...50 °C),

≤ ±0.5 °C (-20...150 °C)

Response time, temp.

T 90 < 4.5 s

Voltage supply

18...36 V DC; 180 mA max.

6.1 Dimensions