TECHNICAL DATA

20

OPTIBAR P 2010 C

www.krohne.com

04/2014 - 4002622502 - MA OPTIBAR P2010C R02 en

6.1 Technical data

INFORMATION!

The following data is provided for general applications. If you require data that is more
relevant to your specific application, please contact us or your local sales office.

Additional information (certificates, special tools, software,...) and complete product
documentation can be downloaded free of charge from the website (Download Center).

Measuring system

Measuring principle

Piezoresistive measuring cell

Application range

Measurement of gauge and absolute pressure in gases and liquids

Measuring range

-1...40 bar / -14.5...580 psi; refer also to chapter "Measuring ranges"

Measuring accuracy

Reference conditions

Medium: air

Temperature: ambient temperature

Ambient pressure: 1013 mbar / 14.7 psi

Nominal position: vertical, pressure port down

Power supply: 24 VDC

Pressure type

Gauge pressure / absolute pressure

Measuring accuracy according to

IEC 60770 (terminal based)

(Hysteresis, non-linearity, non-

repeatability)

Nominal pressure (P

N

) < 0.4 bar / 5.8 psi: ≤± 0.5% of URL

Nominal pressure (P

N

) > 0.4 bar / 5.8 psi: ≤± 0.25% of URL

(URL = Upper Range Limit)

Ambient temperature effect on

zero and span

Nominal pressure (P

N

) < 0.4 bar / 5.8 psi:

≤± 1.5% of URL in compensated range of 0...+50°C / +32...+122°F

Nominal pressure (P

N

) > 0.4 bar / 5.8 psi:

≤± 0.75% of URL in compensated range of -10...+85°C / +14...+185°F

Nominal pressure (P

N

) = -1...0 bar / -14.5...0 psi: ≤± 0.75% of URL

Long-term stability

≤±0.1% of URL within one year under reference conditions

Step response time

< 10 ms (T90)

Vacuum resistance

P

N

≥ 1 bar / 14.5 psi: vacuum resistant

P

N

< 1 bar / 14.5 psi: on request