beautypg.com

Technical data, 2 technical data – KROHNE DK 46-47-48-800 EN User Manual

Page 27

background image

TECHNICAL DATA

7

27

DK46 - DK800

www.krohne.com

05/2011 - 4000302403 MA DK46-800-R03-en

7.2 Technical data

INFORMATION!

The following data is provided for general applications. If you require data that is more
relevant to your specific application, please contact us or your local representative.

Additional information (certificates, special tools, software,...) and complete product
documentation can be downloaded free of charge from the website (Download Center).

Measuring system

Application range

Flow measurement of liquids and gases

Operating method / measuring principle

Variable area measuring principle

Measurement

Primary measured value

Float position

Secondary measured value

Operating and standard volumetric flow

Measuring accuracy

Directive

VDI / VDE 3513, sheet 2 (q

G

= 50%)

DK46

4.0%

DK47

2.5%

DK48

1.0%

DK800

2.5%

Operating conditions

Temperature

Temperature

Temperature

Temperature

Max. operating temperature TS

-5...+100°C / +23...+212°F

Pressure

Pressure

Pressure

Pressure

Operating pressure PS

Pressure Equipment Directive 97/23/EC

Test pressure PT

Pressure Equipment Directive 97/23/EC

Max. permitted operating gauge pressure PS at TS = 100°C / 212°F:

DK…/R (stainless steel top and bottom fittings )

10bar / 145psig

1

DK…/N (brass top and bottom fittings )

10bar / 145psig

1

DK…/PV (PVDF top and bottom fittings )

4bar / 58psig

Installation conditions

Inlet and outlet

None

1 higher pressures upon request