Start-up

5.1 Start-up

CAUTION!
When starting up the flowmeter, the following points must be observed:

Compare the actual operating pressure and the process temperature of the system with the
specifications on the nameplate (PS and TS); these limits must not be exceeded.

Make sure materials are compatible.

Close the needle valve at the flowmeters.

Slowly open the shut-off valve upstream and downstream of the flowmeter.

When measuring liquids, vent the pipes carefully.

When measuring gases, increase pressure slowly.

void float impact (e.g. caused by solenoid valves), as this is likely to damage the measuring
section or float.

Open needle valve at the flowmeters and set the required flow rate.

The top edge of the float marks the reading line for flow values:

Figure 5-1: Reading edge

1 Reading edge
2 Floatform AIII
3 Floatform ball