beautypg.com

Technical data – KROHNE OPTIFLUX 4000 EN User Manual

Page 30

background image

6

TECHNICAL DATA

30

OPTIFLUX 4000

www.krohne.com

01/2011 - 4000818502 - HB OPTIFLUX 4000 R02 en

Hazardous areas

Hazardous areas

Hazardous areas

Hazardous areas

ATEX

Please check the relevant Ex documentation for details.

Compact version with IFC 040 C converter:

Compact version with IFC 040 C converter:

Compact version with IFC 040 C converter:

Compact version with IFC 040 C converter:

II 2 GD

Compact version with IFC 100 C converter:

Compact version with IFC 100 C converter:

Compact version with IFC 100 C converter:

Compact version with IFC 100 C converter:

II 2 GD

Compact version with IFC 300 C converter:

Compact version with IFC 300 C converter:

Compact version with IFC 300 C converter:

Compact version with IFC 300 C converter:

II 2 GD or II 2(1) GD

Remote version:

Remote version:

Remote version:

Remote version:

II 2 GD

FM

In combination with IFC 300 converter:

In combination with IFC 300 converter:

In combination with IFC 300 converter:

In combination with IFC 300 converter:

Class I, Div 2, groups A, B, C and D

Class II, Div 2, groups F and G

Class III, Div 2, groups F and G

CSA

In combination with IFC 300 converter:

In combination with IFC 300 converter:

In combination with IFC 300 converter:

In combination with IFC 300 converter:

Class I, Div 2, groups A, B, C and D

Class II, Div 2, groups F and G

IEC-Ex

Compact version with IFC 100 converter:

Compact version with IFC 100 converter:

Compact version with IFC 100 converter:

Compact version with IFC 100 converter:

IIC T4

NEPSI

GYJ05234 / GYJ05237

Ex me ia IIC T6...T3

Ex de ia IIC T6...T3

Ex qe ia IIC T6...T3

Ex e ia IIC T6...T3

Other approvals and standards

Other approvals and standards

Other approvals and standards

Other approvals and standards

Custody transfer

Standard: without verification

Only in combination with IFC 300 converter.

For diameters: DN25...500 (other diameters on request)

Cold water

Cold water

Cold water

Cold water

MI-001 type examination certificate

OIML R49 certificate of conformity

Conformity with ISO 4064 and EN 14154

Liquids other than water

Liquids other than water

Liquids other than water

Liquids other than water

MI-005 type examination certificate

OIML R117 certificate of conformity

Hygiene

PFA liner is FDA approved.

Protection category acc. to

IEC 529 / EN 60529

Standard: IP 66/67 (NEMA 4/4X/6)

Option: IP 68 (NEMA 6P)

IP 68 is only available for separate design and with a stainless steel

connection box.

Vibration resistance

IEC 68-2-6

Random vibration test

IEC 68-2-34

Shock test

IEC 68-2-27