TECHNICAL DATA

6

27

OPTIFLUX 4000

www.krohne.com

01/2011 - 4000818502 - HB OPTIFLUX 4000 R02 en

Operating conditions

Temperature

Temperature

Temperature

Temperature

Process temperature

PTFE: -40...+180°C / -40...+356°F for remote versions

PTFE: -40...+140°C /-40...+284°F for compact versions

PFA: -40...+180°C / -40...+356°F for remote versions

PFA: -40...+140°C / -40...+284°F for compact versions

ETFE: -40...+120°C / -40...+248°F

Hard rubber: -5...+80°C / 23...+176°F

PU: -5...+65°C / 23...+149°F

For Ex versions different temperatures are valid. Please check the

relevant Ex documentation for details.

Ambient temperature

Standard

Standard

Standard

Standard (with aluminium converter housing):

-40…+65°C / -40…+149°F

(Protect electronics against self-heating with ambient temperatures

above 55°C)

Option

Option

Option

Option (with stainless steel converter housing):

-40...+55°C / -40…+130°F

For Ex versions different temperatures are valid. Please check the

relevant Ex documentation for details.

Storage temperature

-50…+70°C / -58…+158°F

Pressure

Pressure

Pressure

Pressure

EN 1092-1

DN2200...3000: PN 2.5

DN1200...2000: PN 6

DN200...1000: PN 10

DN65 and DN100...150: PN 16

DN2.5...50 and DN80: PN 40

Other pressures on request.

ISO insertion length

Optional for DN15...600

ASME B16.5

1/10...24": 150 lb RF

Other pressures on request.

JIS

DN50...1000: 10 K

DN2.5...40: 20 K

Other pressures on request.

Vacuum load

For information on pressure limits depending on liner material see

chapter "Vacuum load".

Pressure ranges for secondary

containment

For DN25...150:

Pressure resistant up to 40 bar / 580 psi

Burst pressure up to approx. 160 bar / 2320 psi

Pressure drop

Negligible