KROHNE BM 702 HART User Manual
Page 9
KROHNE Messtechnik GmbH & Co. KG · Ludwig-Krohne-Str. 5
! D-47058 Duisburg
9/10
Tel.: 0203-301 0
! Fax: 0203-301 389 · e-mail: [email protected]
Remote Operation Instructions BM 70 A/P, BM 700, BM 702 HART
Attachment B
(continued from the previous page)
Process Variables
Status
Scan Device
-----------------------------------
Diagnostics and Test
Calibrate
-----------------------------------
Master reset
Entry Code
Service Code
-----------------------------------
Audit Trail
Drawing Notes ...
Help ...
-----------------------------------
Clear Offline Configuration
Compare Configurations
Configuration Properties
Designations:
Opt
– Optional, depends on device implementation;
Rd
– Read-only variable;
Loc
– Local AMS variable, affects only AMS faceplates and
configuration tabs and is not read/written from/to instrument.
BM 70 A/P /700 /702 Menu Tree AMS
KROHNE BM 70 A/P /700 /702 45f90b02
Hardware test
Loop test
Test relay
Opt
Calibration Management
-----------------------------------
D/A low trim
D/A high trim
Apply values
-----------------------------------
Autodetect tank height
Record tank empty spectrum
Basic Setup
•
Model
Rd
•
Tag
--------------------------------
•
Tank height
•
Tank type
•
Block distance
•
Antenna
•
Antenna Extension
--------------------------------
•
Time constant
--------------------------------
•
Function I
•
Scale 20 mA
•
Scale 4 mA
--------------------------------
•
Function S
Opt
Basis Parameters
•
Tank height
•
Block distance
•
Antenna
•
Distance piece
--------------------------------
•
Stillwell
•
ID Stillwell
--------------------------------
•
Reference offset
•
Tank bottom offset
Process Input
--Measurements/Cfg data--
•
Length unit
•
Length format
Loc
•
Conversion unit
•
Conversion format
Loc
----- Strap Table ------------
•
Level unit
•
Level format
Loc
•
Volume unit
•
Volume format
Loc
---------------------------------
•
Time constant
Analog Output
•
Function I
•
Range I
•
Scale 20 mA
•
Scale 4 mA
Device/HART
•
Model
Rd
•
Manufacturer
Rd
•
Field device revision
Rd
•
Software revision
Rd
•
Hardware revision
Rd
•
Firmware version
Rd
•
Firmware ident.nr.
Rd
•
Write protect
Rd
--------------------------------
•
Tag
•
Polling address
•
Device ID
Rd
•
Universal revision
Rd
•
Num request preams
Rd
•
Num response preams
•
Final asmby num
•
Date
•
Descriptor
•
Message
--------------------------------
•
PV is
•
SV is
•
TV is
•
4V is
Service
•
Min Peak
•
OF Threshold
•
HP Filter
Opt
•
LP Filter
•
Sweep
Opt
•
Empty spect. Type
•
Min Window
--------------------------------
•
Offset
•
Corr. Factor
•
Max Tankheight
•
Fct digital input
Opt
--------------------------------
•
Serial No
•
Option 1
•
Option 2
Relay Output
•
Function S
Opt
•
Type S
Opt
•
Threshold
Opt
•
Hysteresis
Opt
Application
•
Empty spectrum
•
Time constant
•
Tracing velocity
•
Mult. Reflections
•
BD Detect
•
Function FTB
•
Epsilon R
•
Tank type
Strap Table, 1-20
•
Number of points
First 20 pairs
Level " Volume
Strap Table, 41-50
Last 10 pairs
Level " Volume
Strap Table, 21-40
Next 20 pairs
Level " Volume