3. Technical data


3.1 Electrical versions and data:

3.1 OPTISOUND 3040/3050 C VF3*4.GX***VD**X with integrated oscillator SN64-66H:

Supply voltage:............................
(terminal 1, 2 in the connection compartment)

U = 20... 253 AC, 50/60Hz or U = 20... 72V DC
Um = 253V

Signal circuit.......................................
(terminals 3, 4 in the connection compartment)

4 - 20mA with superimposed HART signal
Um = 253V



4. Application conditions


4.1 Permissible ambient temperature:

4.1.1 On the transducer, category 1D or 2D:

OPTISOUND 3040 C

OPTISOUND 3050 C

-20°C... +80°C

-20°C... +80°C



4.1.2 On the electronics housing, category 2D:

Permissible ambient temperature

-40°C... +60°C




4.2 Surface temperature increase:

4.2.1 On the transducer, category 1D or 2D:

OPTISOUND 3040 C

OPTISOUND 3050 C

Process temperature + 30K

Process temperature + 25K



4.2.2 On the electronics housing in zone 21:

Limited by temperature protection to

+98°C

OSOUND3040-3050C-G_V 30667-DE-050920