beautypg.com

KROHNE OPTISWITCH 5100C Relay EN User Manual

Page 27

background image

1

2

3

-50˚C

(-58˚F)

50˚C

(122˚F)

40˚C

(104˚F)

-40˚C

(-40˚F)

70˚C

(158˚F)

0˚C

(32˚F)

100˚C

(212˚F)

150˚C

(302˚F)

200˚C

(392˚F)

250˚C

(482˚F)

Fig. 12: Ambient temperature - Product temperature

1

Product temperature

2

Ambient temperature

3

Temperature range with temperature adapter

Viscosity - dynamic

0.1 … 10,000 mPa s (requirement: with density

1)

Density

0.7 … 2.5 g/cm³ (0.025 … 0.09 lbs/in³);

0.5 … 2.5 g/cm³ (0.018 … 0.09 lbs/in³) by

switching over

Electromechanical data
Cable entry/plug (dependent on the version)
- Single chamber housing

l

1x cable entry M20x1.5 (cable-ø 5 … 9 mm),

1x blind stopper M20x1.5, attached 1x

cable entry M20x1.5

or:

l

1x cable entry ½ NPT, 1x blind stopper

½ NPT, 1x cable entry ½ NPT

or:

l

1x plug M12x1, 1x blind stopper M20x1.5

Screw terminals

for wire cross-section up to 1.5 mm²

(0.0023 in²)

Adjustment elements
Mode switch
- A

Max. detection or overflow/overfill protection

- B

Min. detection or dry run protection

Density switch
- 0.5

0.5 … 2.5 g/cm³ (0.018 … 0.9 oz/in³)

- 0.7

0.7 … 2.5 g/cm³ (0.025 … 0.9 oz/in³)

OPTISWITCH 5100 C, 5150 C - with relay output

27

Supplement

30426

-EN

-060831