beautypg.com

KROHNE OPTISWITCH 5100C Relay EN User Manual

Page 26

background image

Modes (adjustable)
- A

Max. detection or overflow/overfill protection

- B

Min. detection or dry run protection

Measuring accuracy
Hysteresis

approx. 2 mm (0.08 in) with vertical installation

Integration time

approx. 500 ms

Frequency

approx. 1200 Hz

Ambient conditions
Ambient temperature on the housing

-40 … +70 °C (-40 … +158 °F)

Storage and transport temperature

-40 … +80 °C (-40 … +176 °F)

Process conditions
Parameter

Limit level of liquids

Process pressure

-1 … 64 bar (-14.5 … 938 psi) depending on

the process fitting, e.g. flange

OPTISWITCH 5100 C, 5150 C of 316L/

Hastelloy C4 (2.4610)

-50 … +150 °C (-58 … +302 °F)

Process temperature (thread or flange

temperature) with temperature adapter

(option)

- OPTISWITCH 5100 C, 5150 C of

316L/Hastelloy C4

-50 … +250 °C (-58 … +482 °F)

- OPTISWITCH 5100 C, 5150 C

enamelled

-50 … +200 °C (-58 … +392 °F)

- OPTISWITCH 5100 C, 5150 C with

ECTFE coating

-50 … +150 °C (-58 … +302 °F)

- OPTISWITCH 5100 C, 5150 C with

PFA coating

-50 … +150 °C (-58 … +302 °F)

26

OPTISWITCH 5100 C, 5150 C - with relay output

Supplement

30426

-EN
-060831