beautypg.com

3 exchange the electronics – KROHNE OPTISWITCH 3300C NAMUR EN User Manual

Page 26

background image

l

Wrong characteristics selected

à

Set the correct characteristics on the characteristics

reversal switch (overfill protection; dry run protection).

Wiring should be carried out according to the quiescent

current principle.

?

Signal lamp flashes yellow

l

Fault in the electronics

à

Exchange the electronics

?

Signal lamp flashes yellow

l

instrument defective

à

Exchange instrument or return instrument for repair

7.3 Exchange the electronics

In general, all oscillators of series WE60 can be interchanged.

If you want to use an oscillator with a different signal output,

you can download the corresponding operating instructions

manual from our homepage under Downloads.

With EEx d instruments, the housing cover must only be

opened if there is no explosive atmosphere.

Proceed as follows:
1 Switch off power supply
2 Unscrew the housing cover
3 Lift the opening levers of the terminals with a screwdriver
4 Pull the connection cables out of the terminals
5 Loosen the two screws with a screw driver (Torx size T10

or slot 4)

26

OPTISWITCH 3300 C - with NAMUR output

Maintenance and fault rectification

31358

-EN
-060830