4 Mounting

4.1 General instructions

The note of the following general safety instructions:

l

Dismount the lock fitting only in unpressurized condition

l

Use only suitable graphite gasket rings. Make sure that the

graphite gasket rings are not damage. Damaged rings are

no longer tight. If you are not sure, use new rings.

l

Only use approved hexagon screws DIN 912 M8 x 30 of

A4-70 acc. to AD leaflet W2. The corresponding spring

rings B8 must be made of A4 acc. to DIN 7980.

l

Grease the thread of the mounting boss as well as the

thread and the support of the terminal screws with a

suitable lubricant. The lubricant must be suitable for

material combination 316L/316L and for a temperature

range of -50 … +250°C (-58 … +482°F) e.g. Varybond

type NSS-16/7. The threads are already supplied with a

lubricant.

4.2 Mounting procedure

The lock fitting is already premounted.
The numbers in brackets refer to the following illustration.
1 Loosen the screw (6) and remove the locking bracket (4)
2 Screw mounting boss (7) with a resistant seal ring into the

thread of the vessel and tighten the mounting boss (7) on

the hexagon (SW 75)

3 Clean the connection tube of the sensor and the surfaces

of the clamp (1) as well as the pressure screw (11)

carefully and remove grease, oil and dirt. Insert the sensor

into the lock fitting. Slide the tube into the requested

position and hold it

4 Make sure that the sensor is in the correct position (height.

The height adjustment of the sensor determines also the

switching point

5 Tighten the pressure screw (11) with a torque 240 ±10 Nm

(177 ±7 lbf ft)

6 Continue to turn the pressure screw (11) clockwise until the

hexagon surfaces of the pressure screw (11) and the

mounting boss (7) correspond (max. 1/6 turn)

6