Start-up

• Are the wetted components (gasket, flange and probe) resistant to corrosion by the tank

product?

• Does the information given on the nameplate agree with the application?
• Did you connect the equipotential bonding system correctly?
• Ex d applications:

Ex d applications:

Ex d applications:

Ex d applications: Are the cable entries, plugs and adaptors Ex d-approved?

• Ex i applications:

Ex i applications:

Ex i applications:

Ex i applications: Are you using an intrinsically-safe barrier within the correct parameters?

refer to

Ex ia equipment on page 13. The electrical circuit characteristics must not be more

than the maximum intrinsically-safe values.

• Did you install the correct cable entries? Is the terminal compartment correctly sealed?

WARNING!
Make sure that it is safe to supply electrical power. Do a start-up check: