beautypg.com

Installation – KROHNE OPTIFLEX 4300C ATEX EN User Manual

Page 10

background image

2

INSTALLATION

10

OPTIFLEX 4300 C

www.krohne.com

02/2009 - 4000523601 - AD ATEX OPTIFLEX 4300 R01 en

Equipment category II 2 G: all other probe types

Equipment category II 1 D (Ex ia devices only), II 1/2 D, and II 2 D

Temperature

class

Ambient temperature

Flange temperature

[°C]

[°F]

[°C]

[°F]

T6

-40…+60

-40…+140

-50…+60

1

-58…+140

2

-40…+55

-40…+131

-50…+85

1

-58…+185

2

T5

-40…+75

-40…+167

-50…+75

1

-58…+167

2

-40…+70

-40…+158

-50…+100

1

-58…+203

2

T4

-40…+85

-40…+185

-50…+85

1

-58…+185

2

-40…+80

-40…+176

-50…+110

1

-58…+230

2

-40…+75

-40…+167

-50…+135

1

-58…+275

2

T3

-40…+70

-40…+158

-50…+150

1

-58…+302

2

-40…+65

3

-40…+149

4

-50…+180

1

-58…+356

2

-40…+60

3

-40…+140

4

-50…+200

1

-58…+392

2

1 -50°C, if an EPDM gasket is used. -40°C, if a Viton® GLT gasket is used. -20°C, if a Kalrez® 6375 gasket is used.
2 -58°F, if an EPDM gasket is used. -40°F, if a Viton® GLT gasket is used. -4°F, if a Kalrez® 6375 gasket is used.
3 if the device has an adaptor for BM 100 probes, the flange temperature must be less than 150°C
4 if the device has an adaptor for BM 100 probes, the flange temperature must be less than 300°F

Ambient temperature

Flange temperature

Ø2 mm/Ø0.08¨ single

cable probe (HT version)

Ø2 mm/Ø0.08¨ single

cable probe (other

versions)

Other probes

[°C]

[°F]

[°C]

[°F]

[°C]

[°F]

[°C]

[°F]

-40…+85

-40…+185

-50…+300

1

-58…+572

2

-50…+150

1

-58…+302

2

-50…+200

1

-58…+392

2

1 min. -50°C, if an EPDM gasket is used. Min. -20°C, if a Kalrez® 6375 gasket is used. Min. -40°C, if a Viton® GLT gasket is used.

Min. -30°C, if a Metaglas® feedthrough is used. Min. -50°C, if a PEI feedthrough is used.

2 min. -58°F, if an EPDM gasket is used. Min. -4°F, if a Kalrez® 6375 gasket is used. Min. -40°F, if a Viton® GLT gasket is used.

Min. -22°F, if a Metaglas® feedthrough is used. Min. -58°F, if a PEI feedthrough is used.

AD_ATEX_OPTIFLEX4300_en_090528_4000523601_R01_D5D.book Page 10 Thursday, May 28, 2009 6:00 PM