General safety information, 5 atex nameplates, Compact version – KROHNE OPTIFLEX 2200 ATEX EN User Manual
Page 6
1
GENERAL SAFETY INFORMATION
6
OPTIFLEX 2200 C/F
www.krohne.com
04/2013 - 4000861602 - AD ATEX OPTIFLEX 2200 R02 en
1.5 ATEX nameplates
Compact version
Figure 1-1: Compact version, Ex ia nameplate
Figure 1-2: Compact version, Ex d ia / Ex ia tb nameplate
1 ATEX certification agency code
2 Equipment approval category (explosive atmosphere - gas), types of device protection including approved Gas Groups
and temperature classes (T6...T3 or T2 - depends on the probe type) and equipment protection level
3 Equipment category (explosive atmosphere - dust), types of device protection including approved Gas Groups, maxi-
mum surface temperature degree of ingress protection (if fitted with the appropriate cable glands) and equipment
protection level
4 4...20 mA passive - HART output option:
4...20 mA passive - HART output option:
4...20 mA passive - HART output option:
4...20 mA passive - HART output option: Intrinsically-safe circuit data
Fieldbus (FF or PROFIBUS PA) options:
Fieldbus (FF or PROFIBUS PA) options:
Fieldbus (FF or PROFIBUS PA) options:
Fieldbus (FF or PROFIBUS PA) options: Entity or FISCO power supply parameters
5 4...20 mA passive - HART output option:
4...20 mA passive - HART output option:
4...20 mA passive - HART output option:
4...20 mA passive - HART output option: Maximum voltage in accordance with EN 60079-0. Refer to 7 for the input
voltage range.
6 4...20 mA passive - HART output option:
4...20 mA passive - HART output option:
4...20 mA passive - HART output option:
4...20 mA passive - HART output option: Minimum waiting time after power-off before it is safe to open the terminal
compartment
Fieldbus (FF or PROFIBUS PA) options:
Fieldbus (FF or PROFIBUS PA) options:
Fieldbus (FF or PROFIBUS PA) options:
Fieldbus (FF or PROFIBUS PA) options: Entity or FISCO power supply parameters
7 Input voltage range and maximum current (4...20 mA passive - HART) / basic current (FF or PROFIBUS PA)
8 Cable entry type and size (M20×1.5 or ½ NPT)