beautypg.com

Installation – KROHNE OPTIFLEX 2200 ATEX EN User Manual

Page 15

background image

INSTALLATION

2

15

OPTIFLEX 2200 C/F

www.krohne.com

04/2013 - 4000861602 - AD ATEX OPTIFLEX 2200 R02 en

Remote (Field) versions (probe housing only)
Equipment category 1/2 G or EPL Ga/Gb: Ex ia and Ex d ia devices

Temperature

class

Maximum ambient temperature

Max. flange

temperature

Ø2 mm / Ø0.08¨

single cable probe

(HT version)

Ø2 mm / Ø0.08¨

single cable probe

(other versions)

All other probe types

[°C]

[°F]

[°C]

[°F]

[°C]

[°F]

[°C]

[°F]

T6

+51

+123

+49

+120

+49

+120

+60

+185

T5

+70

+158

+70

+158

+70

+158

+60

+185

T4

+80

+176

+80

+176

+80

+176

+60

+185

Temperature

class

Minimum ambient temperature

Min. flange

temperature

Ø2 mm / Ø0.08¨

single cable probe

(HT version)

Ø2 mm / Ø0.08¨

single cable probe

(other versions)

All other probe types

[°C]

[°F]

[°C]

[°F]

[°C]

[°F]

[°C]

[°F]

T6...T2

-40

-40

-40

-40

-40

-40

-20

-4

INFORMATION!
Remote converter

Remote converter

Remote converter

Remote converter
The maximum ambient temperature, T

a

, permitted depends on the temperature class:

T

a

= +60

°

C for class T6

T

a

= +70

°

C for class T5

T

a

= +80

°

C for class T4