Technical data – KROHNE OPTIWAVE 6300C Quickstart EN User Manual
Page 24
4
TECHNICAL DATA
24
OPTIWAVE 6300 C
www.krohne.com
03/2014 - 4000331505 - QS OPTIWAVE 6300 R05 en
Electrical connections
Power supply
Terminals output 1
Terminals output 1
Terminals output 1
Terminals output 1 – Non-Ex / Ex i:
Non-Ex / Ex i:
Non-Ex / Ex i:
Non-Ex / Ex i:
14…30 VDC; min./max. value for an output of 22 mA at the terminal
Terminals output 1
Terminals output 1
Terminals output 1
Terminals output 1 – Ex d:
Ex d:
Ex d:
Ex d:
20…36 VDC; min./max. value for an output of 22 mA at the terminal
Terminals output 2
Terminals output 2
Terminals output 2
Terminals output 2 – Non-Ex / Ex i / Ex d:
Non-Ex / Ex i / Ex d:
Non-Ex / Ex i / Ex d:
Non-Ex / Ex i / Ex d:
10…30 VDC; min./max. value for an output of 22 mA at the terminal (additional
power supply needed – output only)
Cable entry
M20×1.5; ½ NPT
G ½ (not for FM- and CSA-approved devices. Not for stainless steel housings.)
M25×1.5 (for stainless steel housings only)
Cable gland
Standard: none
Options: M20×1.5 (for non-Ex and Ex -approved devices with M20×1.5 and M25×1.5
cable entries); others are available on request
Cable entry capacity (terminal)
0.5…1.5 mm²
Input and output
Current output
Current output
Current output
Current output
Output signal
(Output 1)
4…20 mA HART
®
or 3.8…20.5 mA acc. to NAMUR NE 43
4
Output signal
(Output 2 - optional)
4…20 mA (no HART
®
signal) or 3.8…20.5 mA acc. to NAMUR NE 43
Resolution
±3 µA
Temperature drift
Typically 25 ppm/K
Error signal
High: 22 mA; Low: 3.6 mA acc. to NAMUR NE 43
Approvals and certification
CE
This device fulfils the statutory requirements of the EC directives. The
manufacturer certifies successful testing of the product by applying the CE mark.
Explosion protection
Explosion protection
Explosion protection
Explosion protection
ATEX
KEMA 04ATEX1218 X
II 1 G, 1/2 G, 2 G Ex ia IIC T6...T3;
II 1 D, 1/2 D, 2 D Ex iaD 20 or Ex iaD 20/21 or Ex iaD 21 IP6X T70°C...T95°C;
II 1/2 G, 2 G Ex d[ia] IIC T6...T3;
II 1/2 D, 2 D Ex tD[iaD] A21/20 or Ex tD[iaD] A21 IP6X T70°C...T95°C
IECEx
IECEx KEM 06.0025 X
Ga Ex ia IIC T6…T3; Ex iaD 20 IP6X T70°C…T95°C;
Ga/Gb Ex d[ia] IIC T6…T3; Ex tD[iaD] A21/20 IP6X T70°C…T95°C
FM – Dual Seal-approved
NEC 500
NEC 500
NEC 500
NEC 500
XP-IS / Cl. I / Div. 1 / Gr. ABCD / T6-T1;
DIP / Cl. II, III / Div. 1 / Gr. EFG / T6-T1;
IS / Cl. I, II, III / Div. 1 / Gr. ABCDEFG / T6-T1;
NI / Cl. I / Div. 2 / Gr. ABCD / T6-T1
NEC 505
NEC 505
NEC 505
NEC 505
Cl. I / Zone 0 / AEx d[ia] / IIC / T6-T1;
Cl. I / Zone 0 / AEx ia / IIC / T6-T1;
Cl. I / Zone 2 / AEx nA[ia] / IIC / T6-T1
Hazardous (Classified) Locations, indoor/outdoor Type 4X and 6P, IP66, Dual Seal