Technical data – KROHNE OPTIWAVE 6300C Quickstart EN User Manual

Page 24

background image

4

TECHNICAL DATA

24

OPTIWAVE 6300 C

www.krohne.com

03/2014 - 4000331505 - QS OPTIWAVE 6300 R05 en

Electrical connections

Power supply

Terminals output 1

Terminals output 1

Terminals output 1

Terminals output 1 Non-Ex / Ex i:

Non-Ex / Ex i:

Non-Ex / Ex i:

Non-Ex / Ex i:

14…30 VDC; min./max. value for an output of 22 mA at the terminal

Terminals output 1

Terminals output 1

Terminals output 1

Terminals output 1 Ex d:

Ex d:

Ex d:

Ex d:

20…36 VDC; min./max. value for an output of 22 mA at the terminal

Terminals output 2

Terminals output 2

Terminals output 2

Terminals output 2 Non-Ex / Ex i / Ex d:

Non-Ex / Ex i / Ex d:

Non-Ex / Ex i / Ex d:

Non-Ex / Ex i / Ex d:

10…30 VDC; min./max. value for an output of 22 mA at the terminal (additional

power supply needed – output only)

Cable entry

M20×1.5; ½ NPT

G ½ (not for FM- and CSA-approved devices. Not for stainless steel housings.)

M25×1.5 (for stainless steel housings only)

Cable gland

Standard: none

Options: M20×1.5 (for non-Ex and Ex -approved devices with M20×1.5 and M25×1.5

cable entries); others are available on request

Cable entry capacity (terminal)

0.5…1.5 mm²

Input and output

Current output

Current output

Current output

Current output

Output signal

(Output 1)

4…20 mA HART

®

or 3.8…20.5 mA acc. to NAMUR NE 43

4

Output signal

(Output 2 - optional)

4…20 mA (no HART

®

signal) or 3.8…20.5 mA acc. to NAMUR NE 43

Resolution

±3 µA

Temperature drift

Typically 25 ppm/K

Error signal

High: 22 mA; Low: 3.6 mA acc. to NAMUR NE 43

Approvals and certification

CE

This device fulfils the statutory requirements of the EC directives. The

manufacturer certifies successful testing of the product by applying the CE mark.

Explosion protection

Explosion protection

Explosion protection

Explosion protection

ATEX

KEMA 04ATEX1218 X

II 1 G, 1/2 G, 2 G Ex ia IIC T6...T3;

II 1 D, 1/2 D, 2 D Ex iaD 20 or Ex iaD 20/21 or Ex iaD 21 IP6X T70°C...T95°C;

II 1/2 G, 2 G Ex d[ia] IIC T6...T3;

II 1/2 D, 2 D Ex tD[iaD] A21/20 or Ex tD[iaD] A21 IP6X T70°C...T95°C

IECEx

IECEx KEM 06.0025 X

Ga Ex ia IIC T6…T3; Ex iaD 20 IP6X T70°C…T95°C;

Ga/Gb Ex d[ia] IIC T6…T3; Ex tD[iaD] A21/20 IP6X T70°C…T95°C

FM – Dual Seal-approved

NEC 500

NEC 500

NEC 500

NEC 500

XP-IS / Cl. I / Div. 1 / Gr. ABCD / T6-T1;

DIP / Cl. II, III / Div. 1 / Gr. EFG / T6-T1;

IS / Cl. I, II, III / Div. 1 / Gr. ABCDEFG / T6-T1;

NI / Cl. I / Div. 2 / Gr. ABCD / T6-T1

NEC 505

NEC 505

NEC 505

NEC 505

Cl. I / Zone 0 / AEx d[ia] / IIC / T6-T1;

Cl. I / Zone 0 / AEx ia / IIC / T6-T1;

Cl. I / Zone 2 / AEx nA[ia] / IIC / T6-T1

Hazardous (Classified) Locations, indoor/outdoor Type 4X and 6P, IP66, Dual Seal