beautypg.com

Device description – KROHNE OPTISWIRL 4070 ATEX II2G EN User Manual

Page 8

background image

2

DEVICE DESCRIPTION

8

OPTISWIRL 4070

www.krohne.com

04/2013 - 4000077105 MA OPTISWIRL4070 II2G AD R05 en

Permissible product and ambient temperatures with converter or connection box sensor
installed above the measuring section
As shown in the figure below, the measuring device should be installed so that it is protected
from direct sunlight.

Maximum permissible product and ambient temperatures per temperature class in °C

Maximum permissible product and ambient temperatures per temperature class in °F

Temperature class T6

T5

T4

T3

T2 … T1

T

amb

in °C

60

60

50

60

40

50

60

40

50

60

Nominal size

DN15 … 25

60

75

110

110

175 175

1

125

1

235

1

180

1

125

1

DN40 … 50

60

75

110

110

175 165

115

215

165

115

DN65 … 100

60

75

110

110

175 155

110

200

155

110

DN150 ... 300

60

75

110

110

175 175

130

1

240

1

190

1

130

1

1 Permanent service temperature of connecting cable and cable entry min. 80°C

Temperature class T6

T5

T4

T3

T2 … T1

T

amb

in °F 140

140

122

140

104

122

140

104

122

140

Nominal size

DN15 … 25

140

167

230

230

347 347

1

257

1

455

1

356

1

257

1

DN40 … 50

140

167

230

230

347 329

239

419

329

239

DN65 … 100

140

167

230

230

347 311

230

392

311

230

DN150 ... 300

140

167

230

230

347 347

266

1

464

1

374

1

266

1

1 Permanent service temperature of connecting cable and cable entry min. 176°F