beautypg.com

M8e menu tree ams – KROHNE M8E Converter HART 0101 User Manual

Page 10

background image

Attachment B






















































Loop test

M8E Menu Tree AMS

D/A trim
-------------------------------
Calibration Management

Basic Setup

Flow Units

Totalizer Units

Unit System

Time Constant

--------------------------------

Low Flow Cutoffcontrol

Cufoff ‘On’ value

Cutoff ‘Off‘ value

--------------------------------

Contact B1

--------------------------------

Contact B2

--------------------------------

Device
Identification

Manufacurer

Model

Device ID

Universal Revision

Field Device Revision

Software Revision

Hardware Revision

Firmware Version

Tag

Normal meter size

Type of cone

Discriptor

Message

Date

Final asembly number

Sensor serial number

Production number

Type of instrument

Type of meter

Type of indicator

Type of float

Material float







Designations:

Rd

– Read-only variable;

Loc

– Local AMS variable, affects only AMS faceplates and

configuration tabs and is not read/written from/to instrument.

Sensor
Sensor Limits

Upper Sensor limit

Lower Sensor limit

Totalizer options
-------------------------------
Counter Reset

Process Input

Flow Units

Counter Units

Full Scale

Flow Min

Time Constant

--------------------------------

Low Flow Cutoffcontrol

Cufoff ‘On’ value

Cutoff ‘Off‘ value

--------------------------------
Application info

Fluid

c

Temperature

Pressure

Density

Viscosity

compr. factor



Linearization

Last Table index

Unit System

Full Scale

Flow Unit

Phase fluid

Phase rel. fluid

Pressure reference

Reference density

Volume Flow ref.

--------------------------------
Linearization Table

X0..X12

Y0..Y12



Output
Contact B1

Limit switch control

Flow Value

Count Value

Hysteresis Value

--------------------------------
Contact B2

Limit switch control

Flow Value

Count Value

Hysteresis Value

--------------------------------


HART

Polling Address

Tag

Device ID

Num. of request preams

Num. of response preams




Process Variables
Status
Scan Device
-----------------------------------
Diagnostics and Test
Calibrate
-----------------------------------
Master reset
Reset configuration flag
Error reset
-----------------------------------
Totalizer
Set to default value
Change Writeprotect
Change Password
-----------------------------------
Audit Trail
Record Manual Event
Drawing Notes ...
Help ...
-----------------------------------
Clear Offline Configuration
Compare Configurations
Configuration Properties

This manual is related to the following products: