2.7 Ambient temperature / temperature classes

Because of the influence of the temperature of the product, no fixed temperature class is
assigned to variable area flowmeters. In fact, the temperature class of a device is a function of
the temperature of both the product and the environment. The classification is outlined in the
following tables.

The tables take into account the following parameters:

• Ambient temperature T

amb.

• Product temperature T

m

• Nominal DN
• Heat resistance of the connecting cable

For certain device version, lower values apply due to differing boundary conditions (e.g. lining
materials).

Here the user should consult the technical data sheet.

Maximum permitted product temperature °C

Maximum permitted product temperature °F

INFORMATION!

The maximum permissible product temperatures listed in the tables are valid under
the following conditions:

The measuring device is installed and operated in accordance with the installation
instructions in the installation and operating manual.

It must be ensured that the flowmeter is not heated by the effects of additional heat radiation
(sunshine, neighbouring system components) and thus operated above the permissible
ambient temperature range.

Insulation must be limited to the piping.
Unobstructed ventilation of the indicator part must be ensured.

Maximum permitted product temperature T

m

(°C) as a function of the maximum continuous

operating temperature of the cable T

max

Ambient temp.

Cable T

max

= 70°C

T

max

= 80°C

Cable T

max

= 90°C

-40...+40

180

200

200

-40...+50

135

190

200

-40...+60

85

145

200

Maximum permitted product temperature T

m

(°F) as a function of the maximum continuous

operating temperature of the cable T

max

Ambient temp.

Cable T

max

= 158°F

Cable T

max

= 176°F

Cable T

max

= 194°F

-40...+104

356

392

392

-40...+122

275

374

392

-40...+140

185

293

392