beautypg.com

Device description, 4 flammable products, 5 equipment category – KROHNE H250 M10 ATEX II3D Ex t EN User Manual

Page 6: 6 protection types

background image

2

DEVICE DESCRIPTION

6

H250 M10

www.krohne.com

03/2011 - 4001348101- MA H250/M10-Ex-II3G-AD R01 en

2.4 Flammable products

Atmospheric conditions

An explosive atmosphere is a mixture of air and flammable gases, vapours, mists or dusts under
atmospheric conditions. The following values define it:
T

atm

= -20...+60°C / -4...+140°F and P

atm

= 0.8...1.1 bar.

Outside of this range, no key data are available as to ignition behaviour for most mixtures.

Operating conditions

Variable area flowmeters operate outside of atmospheric conditions, which means that
explosion protection according to Directive 94/9/EC (ATEX) – regardless of the zone assignment

is fundamentally not applicable due to the lack of key safety data for the interior of the

measuring section.

2.5 Equipment category

The flowmeters are designed in category II 3D according to EN61241-0:2006 and EN 61241-
1:2004 for use in zone 22.

2.6 Protection types

The variable area flowmeter is designed with protection type "Protection by enclosure"
according to EN 61241-1:2004. Dust protection is guaranteed by the use of a housing which
provides appropriate protection against penetration by dust.

The marking is: II 3 D Ex tD A22 IP66 T65

II 3 D Ex tD A22 IP66 T65

II 3 D Ex tD A22 IP66 T65

II 3 D Ex tD A22 IP66 T65°C

C

C

C

The marking contains the following information:

CAUTION!
Operation with flammable products is only permitted as long as no explosive fuel/air mixture
builds up on the inside of the flowmeter under operating conditions. The operator is responsible
for ensuring that the flowmeter is operated safely as regards the temperature and pressure of
the products used. In case of operation with flammable products the measuring units must be
included in the periodic pressure tests of the system. When using the device version H250/C...
(PTFE-liner, nonconductive) the min. conductivity of the medium must be 10

-8

S/m, in order to

avoid the electrostatic charge.

The marking contains the following information:

The marking contains the following information:

The marking contains the following information:

The marking contains the following information:

II

IIII

II

Group II explosion protection

3333

Equipment category 3

D

D

D

D

Dust explosion protection

tD

tD

tD

tD

Protection by enclosures

A22

A22

A22

A22

Surface temperature according to method A, use in zone 22

IP66

IP66

IP66

IP66

Foreign bodies and water pollution control

T65

T65

T65

T65°C

C

C

C

Maximum surface temperature of the converter housing without dust coating at ambient

temperature 60°C / 140°F and product temperature 60°C / 140°F

AD_H250_M10_II3D_R01_en_4001248101_PRT.book Page 6 Wednesday, March 30, 2011 11:44 AM