beautypg.com

Temperature limits, 1 temperatures – KROHNE OPTIFLUX 4040 C Ex EN User Manual

Page 9

background image

TEMPERATURE LIMITS

2

9

OPTIFLUX 4040 C

www.krohne.com

09/2010 - 7312232100 - AD EX OPTIFLUX 4040 C R01 en

2.1 Temperatures

The OPTIFLUX 4040 C-EEx compact flowmeter is designed for ambient temperatures in the
range of -40...+60°C.

The allowed process liquid temperature is among others limited by the combustible atmosphere
that (possibly) surrounds the apparatus, which again is determined by the temperature class of
the atmosphere.

Temperature classification DN10...20

Temperature classification DN10...20

Temperature classification DN10...20

Temperature classification DN10...20

Temperature classification DN25...150

Temperature classification DN25...150

Temperature classification DN25...150

Temperature classification DN25...150

Temperature
(for gasses)

Max. surface
temperature
(for dusts)

Maximum process liquid temperature

T

a

≤ 40°C

T

a

≤ 50°C

T

a

≤ 60°C

T6

T85°C

75°C

70°C

70°C

T5

T100°C

95°C

90°C

75°C

T4

T135°C

130°C

115°C

75°C

T3

T180°C

150°C

115°C

75°C

Temperature
(for gasses)

Max. surface
temperature
(for dusts)

Maximum process liquid temperature

T

a

≤ 40°C

T

a

≤ 50°C

T

a

≤ 60°C

T6

T85°C

70°C

70°C

70°C

T5

T100°C

85°C

85°C

85°C

T4

T135°C

120°C

120°C

115°C

T3

T180°C

180°C

180°C

115°C

Use heat-resistant cables

No

No

Yes