Technical data – KROHNE OPTIFLUX 1000 Quickstart EN User Manual
Page 17
TECHNICAL DATA
4
17
OPTIFLUX 1000
www.krohne.com
04/2014 - 4002298502 - QS OPTIFLUX 1000 R06 en
EN 1092-1
ASME B16.5
Compact version with
Compact version with
Compact version with
Compact version with
IFC 050 (10
IFC 050 (10
IFC 050 (10
IFC 050 (10°))))
a = 101 mm / 3.98"
b = 157 mm / 6.18"
c = 260 mm / 10.24"
1
Total height = H + a
1 The value may vary depending on the used cable glands.
INFORMATION!
•
All data given in the following tables are based on standard versions of the flow sensor only.
•
Especially for smaller nominal sizes of the flow sensor, the signal converter can be bigger
than the flow sensor.
•
Note that for other pressure ratings than mentioned, the dimensions may be different.
•
For full information on signal converter dimensions see relevant documentation.
Nominal size
Dimensions [mm]
Approx. weight
[kg]
DN
L
H
W
10
68
137
47
1.7
15
68
137
47
1.7
25
54
147
66
1.7
40
78
162
82
2.6
50
100
151
101
4.2
80
150
180
130
5.7
100
200
207
156
10.5
150
200
271
219
15.0
Nominal size
Dimensions [inch]
Approx. weight
[lb]
ASME
L
H
W
3/8"
2.68
5.39
1.85
3.7
½
"
2.68
5.39
1.85
3.7
1"
2.13
5.79
2.6
3.7
1½"
3.07
6.38
3.23
5.7
2"
3.94
5.94
3.98
9.3
3"
5.91
7.08
5.12
12.6
4"
7.87
8.15
6.14
23.1
6"
7.87
10.67
8.62
33.1