beautypg.com

Electrical connections – KROHNE IFC 100 Converter Quickstart EN User Manual

Page 15

background image

ELECTRICAL CONNECTIONS

3

15

IFC 100

www.krohne.com

07/2010 - 4000124104 - QS IFC 100 R04 en

3.4.4 Preparing field current cable C, connection to signal converter

• Field current cable C is not part of the scope of supply.
• Bending radius: ≥ 50 mm / 2"

Required materials:

• Shielded, at least 2-wire copper cable with suitable heat-shrinkable tubing
• Insulating tubing, size according to the cable being used
• DIN 46 228 wire end ferrules: size according to the cable being used

Length and cross-section of field current cable C

DANGER!
A shielded two-wire copper cable is used as the field current cable. The shielding MUST

MUST

MUST

MUST be

connected in the housing of the measuring sensor and signal converter.

INFORMATION!
Assembly materials and tools are not part of the delivery. Use the assembly materials and tools
in compliance with the applicable occupational health and safety directives.

Length

Cross-section A

F

(Cu)

[m]

[ft]

[mm

2

]

[AWG]

0...150

0...500

2 x 0.75 Cu

1

2 x 18

150...300

500...1000

2 x 1.50 Cu

1

2 x 14

300...600

1000...2000

2 x 2.50 Cu

1

2 x 12

1 Cu = copper cross-section