HT instruments HT701 User Manual
Page 22

HT701
EN - 21
Resistance
Range Resolution Accuracy
Max voltage
open circuit
Overload protection
1000.0
0.1
(0.5%rdg+2dgt)
Approx. 0.25V
1000VDC/ACrms
10.000k
0.001k
100.00k
0.01k
1000.0k
0.1k
10.000M
0.001M
40.00M
0.01M
Continuity test
Range Accuracy Buzzer
Open circuit voltage Overload protection
400.0
(0.5%rdg+2dgt) <30
Approx. 1.2V
1000VDC/ACrms
Diode test
Range
Accuracy
Test current Open circuit voltage Overload protection
2.000V
(0.5%rdg+2dgt)
0.6mA 2.5V
1000VDC/ACrms
Frequency of AC Voltage and AC Current
Range Resolution Accuracy
Minimum duration
of pulse
Overload protection
100.00Hz 0.01Hz
(0.1%rdg+5dgt)
10µs
1000VDC/ACrms
max 440mA
1000.0Hz 0.1Hz
10.000kHz 0.001kHz
100.00kHz 0.01kHz
Signal sensitivity for frequency measure
Function Range
Sensitivity (sinusoidal waveform)
10Hz ÷ 10kHz
10kHz ÷ 100kHz
AC mV
100.00mV 15.00mV
1000.0mV 150.0mV
AC V
10.000V 1.500V
100.00V 3V
-
1000.0V 30V
-
AC mA
100.00mA 15.00mA
-
400.0mA 30mA
-
Capacitance
Range Resolution Accuracy Measuring
time
Overload
protection
10.000nF 0.001nF
(1.2%rdg+80dgt)
0.7s
1000VDC/ACrms
100.00nF 0.01nF
(1.2%rdg+20dgt)
1000.0nF 0.1nF
(1.2%rdg+2dgt)
10.000
F 0.001F
100.00
F 0.01F
1000.0
F 0.1F
3.75s
10.000mF 0.001mF
(1.2%rdg+20dgt)
7.5s
40.00mF 0.01mF
(1.2%rdg+80dgt)