beautypg.com

Warning – HT instruments HT9 User Manual

Page 11

background image

HT6-HT8-HT9

EN - 10

5.4. CONTINUITY

TEST

WARNING

Before carrying out any continuity test, check that the resistance to be
measured is not live. Failure to respect this prescription may seriously harm
the operator.

Fig. 6: Continuity test

1. Connect the measuring leads L1 and L2 to the object

to be tested (see Fig. 6).

2. The instrument switches on automatically together with

led RX (see Fig. 2 – no. 6) and the buzzer

sounds

continuously in case the result of the continuity test is
positive.

3. The continuity test is active

if the resistance to be

tested is

lower than 500k

.


In case of measurements in environments with poor light,
press the Torch button (see Fig. : 1 – no. 7) to activate the
white LED pointer.