beautypg.com

Specifications warranty, Contact information, Safety – American Power Conversion Back-UPS CS 500 User Manual

Page 2: Service, Item type specification

background image

Item

Type

Specification

Input

Voltage

220 Vrms Nominal

Frequency

45-55 Hz

Brownout Transfer

165 Vrms, typical

Over-voltage Transfer

266 Vrms, typical

Output

UPS Capacity (total)

500 VA / 300 W

Voltage - On Battery

220 Vrms + 8%

(step-approximated sine wave)

Frequency - On Battery

120 Hz + 3 Hz

Transfer Time

8 ms typical, 10 ms maximum

Protection and Filter AC Surge Protection

Full time, 160 joules

Overcurrent Protection

Resettable circuit breaker

Battery (lead-acid)

Type (maintenance free)

12V, 4.5 amp-hour

Average Life

2-5 years

Typical Recharge Time

16 hours

Physical

Net Weight

7.2 lb. (3.3 kg.)

Size

13.3 (H) x 8.2 (W) x 21.3 (D) cm

Operating Temperature

0

o

C to 40

o

C

Storage Temperature

-15

o

C to 45

o

C

Operating Relative Humidity

5 to 95% non-condensing

Operating Elevation

0 to 10,000 ft (0 to 3,000 m)

Specifications

Warranty

Service

Contact Information

The standard warranty is 2 years from the date of purchase. APC will ship the replacement unit once

the defective unit is received by the repair department or cross-ship upon the provision of a valid

credit card number. The customer pays for shipping to APC, and APC pays ground freight

transportation costs back to the customer.

Please DO NOT RETURN the unit to the place of purchase under any circumstances.
1.

Consult the Troubleshooting section to eliminate common problems.

2.

Ensure the Circuit Breaker is not tripped (see Troubleshooting section).
If you still have problems or questions, please contact APC via the internet or at
the phone numbers listed in the Contact Information section.

3.

Before contacting APC, please be sure to record the date purchased, model and
serial number (on bottom of unit).

4.

Be prepared to troubleshoot the problem over the telephone with a Technical
Support Representative. If this is not successful, the representative will issue a
Return Material Authorization Number (RMA#) and a shipping address.
Pack the unit in its original packaging. If the original packaging is not available,
ask APC Technical Support about obtaining a new set. Pack the unit properly to
avoid damage in transit. Never use foam beads for packaging. Damage
sustained in transit is not covered under the warranty (insuring the package for
full value is recommended).

8.

Write the RMA# on the outside of the package.

9.

Return the unit by insured carrier to the address given to you by APC.

APC China (Phone)

8610-85299888

Website

http://www.apcc.com/ch

Online Technical Support

http://support.apcc.com/ch

American Power Conversion

132 Fairgrounds Road
West Kingston, RI USA 02892

Safety

This section contains important instructions that should be followed during installation
and maintenance of the Back-UPS. It is intended for APC customers who setup, install,
relocate, or maintain APC equipment.
This equipment is intended for installation in a temperature-controlled indoor area (see
Specifications for exact temperature range), free of conductive contaminants.

WARNING! Battery Safety

• This unit contains no user-serviceable parts. This equipment contains

potentially hazardous voltages. Do not attempt to disassemble the unit.

Repairs are performed only by factory trained service personnel.

• Do not dispose of batteries in a fire. The batteries may explode.
• Do not open or mutilate batteries. They contain an electrolyte which is

toxic and harmful to the skin and eyes.

Batteries must be recycled. Deliver the entire Back-

UPS to an appropriate recycling facility, or ship it to APC