Doric Instruments 1000 Pro Series Digital Panel meters are suitable User Manual
Page 8

7
1000-DCV and 1000-ACV
AC or DC Voltmeters accept and display voltage ranges from
+/-199.9mV to +/-600Volts. The range is selected by connecting
the input to the proper screw terminal located at the rear of the
unit. See chart on page 5.
Range Table
RangeVDC Accuracy Resolution
0 to 199.9mV
0.5%
0.1mV
0 to 1.999V
0.5% 1mV
0 to 19.99V
0.5% 10.0mV
0 to 199.9V
0.5%
0.1V
0 to 600V
0.5%
1V
1000-DCA DC Current
DC Ammeters accept and display current ranges from +/-1.999mA
to +/-5.00A. The range is selected by connecting the input to the
proper screw terminal located at the rear of the unit. See chart on
page 5 .
Range Table
Range ADC Accuracy Resolution
0 to ±1.999mA
0.5% 1uA
0 to ± 19.99mA
0.5% 10uA
0 to ± 199.9mA
0.5%
100uA
0 to ± 1.999A
0.5%
1mA
0 to ± 5.00 A 0.5% 10mA