Calibration port, 11 5 s sp pa ar re e p pa ar rt ts s, 11 6 w wa ar rr ra an nt ty y – Detcon 971-042200-00L User Manual
Page 6
![background image](/manuals/366775/6/background.png)
1
1..5
5 S
SP
PA
AR
RE
E P
PA
AR
RT
TS
S
P
Paarrtt#
#
D
Deessccrriip
pttiio
on
n
2840
Power switch
2842
Power indicator lamp
2841
Flow fualt indicator lamp
5151-02
Flow fault circuit assembly
3518
24 VDC pump
3489
1000 ml/m flow meter with valve
3606-SD1/SD2
220VAC to 24VDC power supply assembly
8236
Moisture filter pot
8236-ORF
Moisture filter pot replacement filter
1
1..6
6 W
WA
AR
RR
RA
AN
NT
TY
Y
Detcon Inc., as manufacturer, warrants under intended normal use each new Model 971-04220-00L gas detection system
to be free from defects in material and workmanship for a period of one year from the date of shipment to the original
purchaser. Sensor assembly warranties are explained in their respective instruction manuals. All warranties and service
policies are FOB the Detcon Inc. facility located in The Woodlands, Texas.
Detcon Model 971-042200-00L Gas Detection System PG.6
6" of
vent
tube
0
100
200
300
400
500
CAL PORT
SET
FLOW
SAMPLE
PORT
detcon inc.
HOUSTON, TEXAS
SAMPLE DRAW
GAS DETECTION SYSTEM
Calibration
Port
Fixed flow
regulator
Span gas
cylinder
Teflon
tubing
1/4"
Tee
500 ml/m
1000