Symptom:
Power
indicator does not light up.
Cause:
Defective power outlet, power cord, or internal power supply.
Solution:
Have your unit’s power supply or
Power
LED replaced. Ask for
dealer assistance.
Symptom:
Partition
indicator lights up.
Cause:
Hub has partitioned a port.
Solution:
If port partitioning has occurred, the hub will automatically enable
the port when the faulty condition disappears.
Symptom:
Link/Traffic
indicator remains unlit after making a connection.
Cause:
Workstation’s network adapter, the cable, or the hub port is defective.
Solution:
Verify that the hub and attached device are powered on. Be sure the
cable is plugged into both the hub and corresponding device. Verify
that the proper cable type is used (Chapter 2), and that its length
does not exceed 100 meters. Check the adapter on the attached
device and cable connections for possible defects. Replace the
defective adapter or cable if necessary
Use the diagnostic procedures described in the following section to verify that
all other system components are functioning properly. If you still cannot
resolve the problem, contact your Accton distributor for assistance.