Troubleshooting – WEN 56352 3500 Watt manual User Manual
Page 33

29
TROUBLESHOOTING
IMPORTANT: If trouble persists please call our customer help line at (800) 232-1195 M-F 8-5 
Central Time. 
Problem
Cause
Solution
Engine will not 
start 
Engine switch is set 
to "OFF". 
Set engine switch to "ON".
Fuel valve is turned 
to "OFF". 
Turn fuel valve to "ON" position.
Choke is open.
Close the choke
Engine is out of fuel. Add gasoline.
Engine is filled with 
contaminated or old 
gasoline. 
Change the gasoline in the gas tank.
Spark plug is dirty.
Clean spark plug.
Spark plug is 
broken. 
Replace spark plug.
Generator is not on 
level surface. 
Move generator to a level surface to prevent low oil shutdown 
from triggering. 
Oil is low.
Add or replace oil.
Engine runs but 
there is no 
electrical output 
Circuit reset button 
is off. 
Wait for 2 minutes and push the circuit reset button to the 
"ON" position. 
Bad connecting 
wires/cables. 
If you are using an extension cord, try a different one.
Bad electrical device 
connected to 
generator. 
Try connecting a different device.
Generator runs but 
does not support 
all electrical 
devices 
connected. 
Generator is 
overloaded. 
Perform these steps: 
1. Turn off all electrical devices. 
2. Unplug all electrical devices. 
3. Turn off generator. 
4. Wait several minutes. 
5. Restart generator. 
6. Try connecting fewer electrical loads to the generator. 
Short in one of the 
connected devices. Try disconnecting any faulty or short-circuited electrical loads. 
Air cleaner is dirty.
Clean or replace air cleaner.
DC No Power
Power cord plug not 
securely in place 
Twist and push power cord plug into receptacle until contact is 
made with bottom of receptacle. 
Protective fuse is 
blown 
Contact our customer service help line at (800) 232-1195.