USGlobalsat TR-206 User Guide User Manual
Page 60

TR-206
page 60
Command
Code Word Concerning Parameter
Ping
PI
=tolerance time of GPS fix
Periodic report
PR
=report interval
Motion moving
MM
=moving report interval
Motion static
MS
=moving static interval
Link Server
LI
Command format:
“password,simple command,simple command,simple command”
Note:
Do include spaces between the commas. Otherwise, the
TR-206 would not be able to distinguish what is the command.
Example 1: Ping the TR-206 and set the tolerance time of GPS
fix as 3 minutes. The password is 520JX
The command is
“520JX,PI=180”
Example 2: Switch the mode of the TR-206 to motion mode. Set
the moving report interval as 30 seconds and static report
interval as 30 minutes. The password is 7777.
The command is
“7777,MM=30,MS=1800”
Example 3: Make the TR-206 to report periodically with the
interval of factory value. The password is VICTORY.
The command is
“VICTORY,PR”