beautypg.com

Grounding the pump, Warning – SANDPIPER MSB25 User Manual

Page 12

background image

msb1dl5sm-rev0813

Models MSB1 & MSB25 Page 10

GROUNDING THE PUMP

Take action to prevent static sparking.

F i r e o r e x p l o s i o n c a n r e s u l t ,

especially when handling flammable liquids.

The pump, piping, valves, containers or

other miscellaneous equipment must be

grounded.

WARNING

To reduce the risk of static electrical sparking, this pump must be grounded.

Check the local electrical code for detailed grounding instruction and the

type of equipment required, or in the absence of local codes, an industry

or nationally recognized code having jurisdiction over specific installations.

This 8 foot long (244 centimeters) Ground

Strap, part number 920-025-000 can be

ordered as a service item.

To be fully groundable, the pumps must be

ATEX Compliant. Refer to pump data sheet

for ordering.

One eyelet is fastened to the pump hardware.

One eyelet is installed to a true earth ground. (Requires a 5/16"

or 8mm maximum diameter bolt.