m05conductiveacetal-rev0812
Model M05 Conductive Acetal Design Level 2 Page 1
Quality System
ISO9001 Certified
Environmental
Management System
ISO14001 Certified
M05 Conductive Acetal
Design Level 2
Ball Valve
Air Operated
Double-Diaphragm Pump
ENGINEERING, PERFORMANCE
& CONSTRUCTION DATA
MARATHON
®
pumps are designed to be powered only by compressed air.
II 2GD T5
II 2 G c T5
II 3/2 G c T5
II 2 D c T100°c
NITRILE
- General purpose, oil-resistant. Shows good solvent, oil, water and hydraulic fluid resistance. Should not be used with highly polar solvents like
acetone and MEK, ozone, chlorinated hydrocarbons and nitro hyrdrocarbons.
PTFE
- Chemically inert, virtually impervious. Very few chemicals are known to react chemically with PTFE- molten alkali metals, turbulent liquid or
gaseous fluorine and a few fluoro-chemicals such as chlorine trifluoride or oxygen difluoride which readily liberate free fluorine at elevated temperatures.
CONDUCTIVE ACETAL
-
Tough, impact resistant, ductile. Good abrasion resistance and low friction surface. Generally inert, with good chemical resistance
except for strong acids and oxidizing agents.
SANTOPRENE
-
Injection molded thermoplastic elastomer with no fabric layer. Long mechanical flex life. Excellent abrasion resistance.
MATeRiALs
Maximum*
Minimum*
Operating Temperatures
iNTAke/DisCHARge PiPe size
1/2" NPT(Internal) or 1/2" BSPT (Tapered)
1" NPT(External) or 1" BSPT (Tapered)
CAPACiTy
0 to 14 gallons per minute
(0 to 52 liters per minute)
AiR VALVe
No-lube, no-stall
design
sOLiDs-HANDLiNg
Up to .125 in. (3mm)
HeADs UP TO
100 psi or 231 ft. of water
(7 Kg/cm
2
or 70 meters)
DisPLACeMeNT/sTROke
.026 Gallon / .098 liter
CAUTiON! Operating temperature limitations are as follows:
190° F
88° C
-10° F
-23° C
220° F
104° C
-35° F
-37° C
190° F
88° C
-20° F
-29° C
275° F
135° C
-40° F
-40° C
CAUTiON: Nonmetallic pumps and plastic components are not UV stabilized. Ultraviolet radiation can damage these parts and negatively affect material
properties. Do not expose to UV light for extended periods of time.
For specific applications, always consult the Warren Rupp “Chemical Resistance Chart”
Maximum and Minimum Temperatures are the limits for which these
materials can be operated. Temperatures coupled with pressure affect the
longevity of diaphragm pump components. Maximum life should not be
expected at the extreme limits of the temperature ranges.