beautypg.com

M05 conductive acetal design level 2 ball valve, Air operated double-diaphragm pump, Ii 2gd t5 – SANDPIPER M05 Conductive Acetal User Manual

Page 3

background image

m05conductiveacetal-rev0812

Model M05 Conductive Acetal Design Level 2 Page 1

Quality System

ISO9001 Certified

Environmental

Management System

ISO14001 Certified

M05 Conductive Acetal

Design Level 2

Ball Valve

Air Operated

Double-Diaphragm Pump

ENGINEERING, PERFORMANCE

& CONSTRUCTION DATA

MARATHON

®

pumps are designed to be powered only by compressed air.

II 2GD T5

II 2 G c T5

II 3/2 G c T5

II 2 D c T100°c

NITRILE

- General purpose, oil-resistant. Shows good solvent, oil, water and hydraulic fluid resistance. Should not be used with highly polar solvents like

acetone and MEK, ozone, chlorinated hydrocarbons and nitro hyrdrocarbons.

PTFE

- Chemically inert, virtually impervious. Very few chemicals are known to react chemically with PTFE- molten alkali metals, turbulent liquid or

gaseous fluorine and a few fluoro-chemicals such as chlorine trifluoride or oxygen difluoride which readily liberate free fluorine at elevated temperatures.

CONDUCTIVE ACETAL

-

Tough, impact resistant, ductile. Good abrasion resistance and low friction surface. Generally inert, with good chemical resistance

except for strong acids and oxidizing agents.

SANTOPRENE

-

Injection molded thermoplastic elastomer with no fabric layer. Long mechanical flex life. Excellent abrasion resistance.

MATeRiALs

Maximum*

Minimum*

Operating Temperatures

iNTAke/DisCHARge PiPe size

1/2" NPT(Internal) or 1/2" BSPT (Tapered)

1" NPT(External) or 1" BSPT (Tapered)

CAPACiTy

0 to 14 gallons per minute

(0 to 52 liters per minute)

AiR VALVe

No-lube, no-stall

design

sOLiDs-HANDLiNg

Up to .125 in. (3mm)

HeADs UP TO

100 psi or 231 ft. of water

(7 Kg/cm

2

or 70 meters)

DisPLACeMeNT/sTROke

.026 Gallon / .098 liter

CAUTiON! Operating temperature limitations are as follows:

190° F

88° C

-10° F

-23° C

220° F

104° C

-35° F

-37° C

190° F

88° C

-20° F

-29° C

275° F

135° C

-40° F

-40° C

CAUTiON: Nonmetallic pumps and plastic components are not UV stabilized. Ultraviolet radiation can damage these parts and negatively affect material

properties. Do not expose to UV light for extended periods of time.

For specific applications, always consult the Warren Rupp “Chemical Resistance Chart”

Maximum and Minimum Temperatures are the limits for which these

materials can be operated. Temperatures coupled with pressure affect the

longevity of diaphragm pump components. Maximum life should not be

expected at the extreme limits of the temperature ranges.