beautypg.com

SANDPIPER M05 Conductive Acetal User Manual

Page 21

background image

m05conductiveacetal-rev0812

Model M05 Conductive Acetal Design Level 2 Page 19

DiAPHRAgM seRViCiNg

To service the diaphragms first

shut off the suction, then shut off the

discharge lines to the pump. Shut

off the compressed air supply, bleed

the pressure from the pump, and

disconnect the air supply line from the

pump. Drain any remaining liquid from

the pump.

step #1: See the pump composite

repair parts drawing, and the diaphragm

servicing illustration.

Using a 1/2" wrench or socket,

remove the 16 capscrews (items 9 &

10), and flanged nuts that fasten the

elbows (items 16 and 17) to the outer

chambers (items 13). Remove the

elbows with the manifolds and spacers

attached.

step #2: Removing the outer

chambers.

Using a 1/2" wrench or socket,

remove the 16 capscrews (items 9

and 10), and flanged nuts that fasten

the outer chambers, diaphragms, and

intermediate (item 4) together.

step #3: Removing the diaphragm

assemblies.

Use a 3/4" (19mm) wrench or

six pointed socket to remove the

diaphragm assemblies (outer plate,

diaphragm, and inner plate) from the

diaphragm rod (item 30) by turning

counterclockwise.

Insert a 6-32 set screw into the

smaller tapped hole in the inner

diaphragm plate (item 27). Insert

the protruding stud and the 6-32

fastener loosely into a vise. Use a

3/4" wrench or socket to remove the

outer diaphragm plate (item 26) by

turning counterclockwise. Inspect the

diaphragm (item 14) for cuts, punctures,

abrasive wear or chemical attack.

Replace the diaphragms if necessary.

step #4: Installing the diaphragms.

Push the threaded stud of the outer

diaphragm plate through the center hole

of the diaphragm. Thread the inner plate

clockwise onto the stud. Insert the loose

assembly with the above 6-32 fastener

back into the vise. Use a torque wrench

to tighten the diaphragm assembly

together to 90 in lbs. (10.17 Newton

meters) 120 in lbs. Santoprene (13.56

Newton meters). Allow a minimum of 15

minutes to elapse after torquing, then

re-torque the assembly to compensate

for stress relaxation in the clamped

assembly.

step #5: Installing the diaphragm

assemblies to the pump.

Make sure the bumper (item 6) is

installed over the diaphragm rod.

Thread the stud of the one diaphragm

assembly clockwise into the tapped

hole at the end of the diaphragm rod

(item 30) until the inner diaphragm plate

is flush to the end of the rod. Insert rod

into pump.

Align the bolt holes in the diaphragm

with the bolt pattern in the intermediate

(item 4).

Fasten the outer chamber (item

13) to the pump, using the capscrews

(items 9 and 10) and flanged nuts.

On the opposite side of the pump,

pull the diaphragm rod out as far as

possible. Make sure the bumper (item

6) is installed over the diaphragm rod.

Thread the stud of the remaining

diaphragm assembly clockwise into the

tapped hole at the end of the diaphragm

rod (item 30) as far as possible and

still allow for alignment of the bolt

holes in the diaphragm with the bolt

pattern in the inner chamber. Install

diaphragms with convolutions facing

towards center of pump. See sectional

view on previous page.

Fasten the remaining outer chamber

(item 13) to the pump, using the

capscrews (items 9 and 10) and flanged

nuts.

step #6: Re-install the elbow/

spacer/manifold assemblies to the

pump, using the capscrews (items 9 &

10) and flanged nuts.

The pump is now ready to be

re-installed, connected and returned to

operation.
OVeRLAy DiAPHRAgM seRViCiNg

The overlay diaphragm (item 15) is

designed to fit snugly over the exterior of

the standard TPE diaphragm (item14).

ONe PieCe DiAPHRAgM seRViCiNg

(Bonded PTFE with intergral plate)

The One Piece diaphragm has a

treaded stud installed in the intergral

plate at the factory. The inner diaphragm

plate has a through hole instead of a

threaded hole.

Place the inner plate over the

diaphragm stud and thread the first

diaphragm / inner plate onto the

diapragm rod only until the inner plate

contacts the rod. Do not tighten.

A small amount of grease may be

applied between the inner plate and the

diaphragm to facilitate assembly.

Insert the diaphragm / rod assembly

into the pump and install the outer

chamber. Turn the pump over and

thread the second daiphragm / inner

plate onto the diaphragm rod. Turn the

diapragm until the inner plate contacts

the rod and hand tighten the assembly.

Continue tightening until the bolt holes

align with the inner chamber holes. DO

NOT LEAVE THE ASSEMBLY LOOSE.

Read these instructions

completely, before in-

stallation and start-up.

It is the responsibility of

the purchaser to retain

this manual for reference. Failure to

comply with the recommendations stated

in this manual will damage the pump, and

void factory warranty.

iMPORTANT