High off low, Air inflation and confined space-cleaning, Warning – Rainbow e2 (Silver) User Manual
Page 8: For normal cleaning operations and air cleaning, Rinsing the hepa neutralizer warning
![background image](/manuals/364071/8/background.png)
AIR INFLATION AND CONFINED SPACE-CLEANING:
This unique Rainbow tool provides users with
the added convenience of two specialized
capabilities: air infl ation and confi ned-space
cleaning.
The
Rainbow Infl ator is the ideal tool for
Infl ator
Infl ator
conveniently infl ating beach balls, infl atable
toys and air mattresses.
The
Rainbow Confi ned-Space Cleaner
is the ideal tool for cleaning hard-to-get-
at areas like refrigerator coils, behind and
under appliances, cabinets or furniture. Coil
cleaner extension can be used in either
suction or blower mode (see illustration).
The
Rainbow Airfl ow Adaptor is used to
ow Adaptor
ow Adaptor
reduce air noise through the air inlet. It is
recommended to use the adaptor when the Rainbow is used as a blower. Simply
snap the Airfl ow Adaptor into the air inlet opening before using the Rainbow
as a blower.
Instructions For Use: To use the Rainbow Infl ator, open the exhaust vent door at
the back of the power unit. Attach the hose to the exhaust opening. Attach Rainbow
curved wand handle to the hose and the infl ator to the handle. Secure the connection
with the button lock. The infl ator pin is then inserted into the tool body. Twist one-
half turn counter-clockwise to lock pin in place. Insert the pin into the infl ator stem of
the object to be infl ated and turn on the power unit. Also, use the Airfl ow Adaptor to
reduce air noise through the air inlet opening during this operation.
AIR
CLEANING
AIR INFLATION
AND CONFINED-
SPACE CLEANING
NOTE:
When using the Rainbow
as an air cleaner,
remove attachments.
The Rainbow is equipped
with low and high speed.
WARNING:
Be sure infl ator pin is
properly locked in place.
If not, it will be blown
forcefully from the
tool body.
FOR NORMAL CLEANING OPERATIONS AND
AIR CLEANING:
Select high-speed setting for maximum
cleaning performance. Low speed can
also be used for air cleaning.
Air Cleaner - The Rainbow cleans the
air you breathe. The air in the average
home contains large amounts of dust,
lint and other foreign substances. Run
your Rainbow without attachments in
any desired area for about an hour
every day. The Rainbow takes the dust
from the air and drowns it in the water.
Humidifi er - In the winter, the air in
the average home often becomes
excessively dry. Run your Rainbow
without attachments to humidify the air you breathe. Using your Rainbow in this
manner daily will help maintain the proper humidity.
Deodorizer / Aromatizer - By adding a few drops of your favorite Rainbow fragrance
Deodorizer / Aromatizer
Deodorizer / Aromatizer
or Rainbow Deodorant Air Freshener to the water while running your Rainbow
without the attachments, the air is quickly freshened and objectionable household
odors removed.
Vaporizer - Place a few drops of an inhalant in the water of your Rainbow basin. Run
Vaporizer
Vaporizer
the Rainbow without attachments and breathe deeply.
HIGH
OFF
LOW
1
REMOVE THE REAR PANEL:
Using a screwdriver, remove
the panel from the back of the
Rainbow by pressing up on the
two latches on the underside of
the rear panel. Move the bottom
of the rear panel towards you,
lifting up.
RINSING
THE HEPA
NEUTRALIZER
WARNING:
Unplug the Rainbow
before servicing.
Do not operate the
Rainbow without the
HEPA Neutralizer.
NOTE:
Do not use detergent or
soap to wash the fi lter.
Use clean water only.
3
RINSING THE HEPA NEUTRALIZER:
A
Place the dirty HEPA Neutralizer in the sink
with the oval opening facing up.
B Fill the oval opening in the HEPA Neutralizer
with cool water from a faucet until the water
comes out of the opening. Continue to let
the water run over the HEPA Neutralizer for
approximately one minute.
C Turn off the water supply. Turn the HEPA
Neutralizer over and tap into the sink so that
the water escapes from the oval opening.
D Repeat steps B and C until no substantial
amount of dirt is seen coming out of
the HEPA Neutralizer. Shake the HEPA
Neutralizer briskly, with oval opening facing
down, to remove any excess water.
E Reinstall the HEPA Neutralizer and rear
panel by following the instructions in
reverse order.
2
REMOVE THE HEPA NEUTRALIZER.
4
DRYING THE HEPA NEUTRALIZER:
A Make sure the vent door is removed
from the rear panel.
B With the water basin empty, set the
Rainbow on the edge of a towel or
other absorbent cloth, such that the
vent door side of the Rainbow is facing
the cloth or towel.
C Install the airfl ow adapter onto the front
of the Rainbow to dampen noise.
D Run the Rainbow on high speed for
approximately 1/2-hour to thoroughly
dry the HEPA Neutralizer.
E Excess water from the rinsing process
may be emitted onto the towel or
absorbent cloth during the fi rst portion
of the 1/2-hour drying time.
F After the HEPA Neutralizer is dry,
replace the vent door.
G If cleaning ability is not adequately
restored
after
the
HEPA
Neutralizer is dry, contact your
Authorized Distributor.
8