Operating StatusTable
Mode
Indicator Light
Status
Cause
Next Operation
Start/Restart
No light
Not generating power.
(Wind speed range:
0 to 3 m/s, 0 to 11KPH,
0 to 6.7MPH)
The power is off,
or the wind is
weak and the
rotor is rotating
below 420rpm or
the DPDT Switch
is on brake position.
Starts in normal
operating mode
Normal
operation
Solid green
Generating power.
(Wind speed range:
3 to 12 m/s,
11 to 43KPH,
6.7 to 27MPH)
When the rotor is
rotating at 0 to 999
rpm
Flashing green
Generating power at
controlled rpm. (Wind
speed range: 12 to 20
m/s, 43 to 72KPH,
27 to 45MPH)
The rpm is limited
to 1000 rpm.
Flashing red
Generating power at
controlled 600rpm.
Voltage
protection
solid red
Generating power at
controlled rpm.
When battery
voltage is full and
exceeds57.2V
Rotor stopped
Recovers to normal
operation when the
voltage drops below
53.2V
Flashing red
Temperature
protection
solid red
Rotor stopped
When the
temperature
of the alternator
cover exceeds
90°C,194°F
or the
temperature
sensor is damaged
Recovers to normal
operation when the
temperature drops
below 60°C, 140°F,
If it is not recovered
over one hour,
contact us
Other
On and off
Intermittent brake
Defective or loose
connection to the
battery
Check battery
connections, the
turbine brushes
and their tracks
11
•Type: We recommend the use of deep cycle batteries (particularly AGM)
to handle the deep charge/discharge cycles in the wind turbine system.
The deep cycle battery has less instant energy than the starting (cranking)
ones used on cars, but greater long-term energy delivery. A car battery will
not last as long when used for repeated deep charged/ discharged cycles.
9. Considerations when choosing Peripheral Materials/Devices
9-1 Batteries
Wind speed:
Over 20m/s,
72KPH, 45MPH
Recovers to normal
operation when
wind speed below
20m/s,72KPH,
45MPH
•Series/Parallel Connections: You have to connect 4 x 12V batteries in
series to get a 48V group. The batteries in series within a group have to