Installation – Lincoln Electric IM961 VANTAGE 400 User Manual
Page 9
![background image](/manuals/363757/9/background.png)
VANTAGE
®
400
1. Output rating in watts is equivalent to volt-amperes at unity power factor. Output voltage is within ± 10% at all loads up to
rated capacity. When welding, available auxiliary power will be reduced.
* To Top of enclosure, add 10.68”(271.3mm) to top of exhaust pipe. Add 6.67”(169.4mm) to top of Lift Bail.
2. Reduced to less than 30V in the CC-stick Mode when VRD (VOLTAGE REDUCTION DEVICE) is on.
A-1
INSTALLATION
A-1
TECHNICAL SPECIFICATIONS - VANTAGE 400 (K2711-1, K2711-2)
Make/Model
Description
Speed (RPM)
Displacement
Starting
Capacities
KUBOTA
cu. in. (ltrs.)
System
4 cylinder
148.5(2.4)
12VDC Battery &
Fuel: 20 gal.
35.4 HP
High Idle 1880
starter
(75.7 L)
(V2403M)
1800 RPM
Bore x Stroke inch (mm)
(Group 34; 650 Oil: 10 Qts. (9.5L)
Full Load 1800 cold crank amps)
3.43 X 4.03
40 Amp Alternator
Radiator Coolant:
Low Idle 1400
(87.1 x 102.4mm)
8.0 Qts. (7.6L)
INPUT - DIESEL ENGINE
RATED OUTPUT @ 104° F (40° C) - WELDER
HEIGHT WIDTH
DEPTH
WEIGHT
35.94* in. 25.30 in 60.00 in.
913 mm
643 mm
1524 mm
LUBRICATION EMISSIONS
FUEL SYSTEM
GOVERNOR
Full Pressure
EPA Tier 4
Mechanical Fuel Pump, Auto air bleed
Electronic
with Full Flow Filter
Interim Compliant
system, Electric shutoff solenoid, Indirect fuel injector.
AIR CLEANER
ENGINE IDLER
MUFFLER
ENGINE PROTECTION
Low noise Muffler:
Shutdown on low oil
Single Element
Automatic Idler
Top outlet can be rotated. pressure & high engine
Made from long life, aluminized steel.
coolant temperature
ENGINE WARRANTY: 2 years / 2000 hours, all non-electric components, 3 years major non-electric compo-
nents . See Perkins warranty for details.
Welding Process
DC Constant Current
DC Pipe Current
Touch-Start™TIG
DC Constant Voltage
Arc Gouging
Output Range
30 TO 500 AMPS
40 TO 300 AMPS
20 TO 250 AMPS
14 TO 36 VOLTS
90 to 450 Amps
Max. Weld OCV
@Rated Load RPM
60 Volts
2
Welding Output
Current/Voltage/Duty Cycle
400A / 36V / 100%
450A / 32V / 100%
300A / 32V / 100%
250A / 30V / 100%
400A / 36V / 100%
450A / 32V / 100%
400A / 36V / 100%
Auxiliary Power
1
12,000 Watts Peak, / 11,000 Watts Continuous, 60 Hz 120/240 Volts Single Phase
19,000 Watts Peak, / 17,000 Watts Continuous, 60 Hz, 240 Volts 3-Phase
PHYSICAL DIMENSIONS
ENGINE
RECEPTACLES AUXILIARY POWER CIRCUIT BREAKER OTHER CIRCUIT BREAKERS
(2) 120VAC Duplex (5-20R) GFCI protected
Two 20AMP for Two Duplex Receptacle 10AMP for Battery Charging Circuit
(1) 120/240VAC Dual Voltage (1) 50AMP for Dual Voltage and for 10AMP for 42V Wire Feeder Power
(Full KVA (14-50R)14-50R)
3-Phase (3-pole)
(1) 240VAC 3-Phase (15-50R)
MACHINE SPECIFICATIONS
RATED OUTPUT @ 104° F (40° C)
.
- GENERATOR
1245 lbs. (559kg.)