Installation, Technical specifications – under- water cooler – Lincoln Electric IM723 UNDER-COOLER CART User Manual
Page 8

A-1
INSTALLATION
UNDER-COOLER CART
A-1
TECHNICAL SPECIFICATIONS – UNDER- WATER COOLER
Model / Make
Under-Cooler Cart K1828-1
Input
100-120 VAC 50/60 Hz 1 Phase
Rated Current Draw
60 Hz (2.8-3.5 Amps)
50 Hz (3.5-5.3 Amps)
Operating Pressure
60 psi (413 kPa) (4.1 bar)
Pump Hydraulic
Rating No Flow
Discharge Pressure (gage)
(Relief Valve Setting)
60 PSIG (414 kPa) (4.14 bar) Max.
No Pressure
Flow Rate
1.66 gal/min (6.28 liter/min) Max.
Pump Hydraulic Rating
(Typical Operation)
Discharge Pressure (gage)
53-57 PSIG (365-393 kPa)
Flow Rate
.45-.60 gal/min (1.7-2.3 liter/min)
Reservoir Capacity
2.0 Gallons (7.6 Liters)
For Use Above Freezing: Clean tap, distilled, or de-ionized water
For Use Below Freezing: 50% water and 50% pure ethylene glycol mixture.
Recommended Coolant
DO NOT USE: Automotive anti-freeze that contains rust inhibitors or leak
stoppers. These coolants will damage the pump and block the small internal
passageways of the heat exchanger, affecting cooling performance. To
acquire the proper coolant contact a local welding distributor.
DO NOT USE: Pre-packaged welding industry coolants. These coolants may
contain oil-based substances, which attack the plastic components of the
cooler. Once added to the cooler, these substances are virtually impossible to
purge from the water lines and heat exchanger.
Weight
Shipping
252 lbs. (114 kg)
Reservoir Full (Water)
267 lbs. (121 kg)
Dimensions
Length
41 in (1041 mm)
Width
27 in (686 mm)
Height (Top Face)
21 in ( 533mm )
Height (TIG Interface)
19 in (483 mm)