ACCESSORIES

INNERSHIELD (FCAW)
CONVERSION

Several changes are needed to convert the unit for
operation with the Innershield (FCAW) process. The
K549-1 or K549-2 Innershield Kits include all the nec-
essary accessories for this conversion and are provid-
ed for this purpose. The following conversions should
be made using the contents of this kit:

1. Change the output polarity to DC(

). See

Work

Cable Installation

in Installation section for details.

2. Install proper drive roll for the wire size selected.

See

Changing Drive Roll

in Maintenance section

for details.

3. Install the proper gun liner and tip for the wire size

selected. See

Component Replacement

in

Maintenance section for details.

4. Remove gas nozzle (if installed) and install gasless

nozzle. To remove, simply unscrew.

5. Load wire into machine and thread into gun and

cable per

Welding Wire Loading

section.

REPLACEMENT PARTS

Complete Gun and Cable Assembly
L8311-6 (K530-4)

Contact Tip .025

(0.6 mm)

S19726-1

Contact Tip .030

(0.8 mm)

S19726-2

Contact Tip .035

(0.9 mm)

S19726-3

Contact Tip .045

(1.2 mm)

S19726-4

Contact Tip-Tapered .025

(0.6 mm)

S20278-1

Contact Tip-Tapered .030

(0.8 mm)

S20278-2

Contact Tip-Tapered .035

(0.9 mm)

S20278-3

Contact Tip-Tapered .045

(1.2mm)

S20278-4

Liner .023 - .030

(0.6 - 0.8 mm)

M16291-2

Liner .030/.035

(0.8/0.9 mm)

M16291-6

Liner .035/.045

(0.9/1.2 mm)

M16291-1

Gas Diffuser
S19728

Gas Nozzle
M16294

Gas Nozzle-Tip Recessed 3/8

(9.5 mm)

Opening I.D.
M16684

Gas Nozzle-Tip Recessed 1/2

(12.7 mm)

Opening I.D.
M16684-1

Gas Nozzle-Tip Recessed 5/8

(15.9 mm)

Opening I.D.
M16684-2

Spot Welding Nozzle
M17846-1

Gasless Nozzle (Innershield Only)
M16418

SP-175T