beautypg.com

Troubleshooting, Troubleshooting guide, Caution – Lincoln Electric IM788 SP-135 Plus User Manual

Page 31

background image

E-4

E-4

TROUBLESHOOTING

Observe Safety Guidelines
detailed in the beginning of this manual.

TROUBLESHOOTING GUIDE

PROBLEMS
(SYMPTOMS)

Arc is unstable – Poor starting

POSSIBLE AREAS OF
MISADJUSTMENT(S)

1. Check for correct input voltage

to machine – 115 vac.

2. Check for proper electrode

polarity for process.

3. Check gun tip for wear or dam-

age – Replace.

4. Check for proper gas and flow

rate for process.

5. Check work cable for loose or

faulty connections.

6. Check gun for damage or

breaks.

RECOMMENDED
COURSE OF ACTION

Contact your local Lincoln
Authorized Field Service Facility.

WELDING PROBLEMS

If for any reason you do not understand the test procedures or are unable to Perform the tests/repairs safely, contact your
LOCAL AUTHORIZED LINCOLN ELECTRIC FIELD SERVICE FACILITY for assistance before you proceed.

CAUTION

PROBLEMS
(SYMPTOMS)

Low or no gas flow when gun
trigger is pulled. Wire feed, weld
output and fan operate normally.

POSSIBLE AREAS OF
MISADJUSTMENT(S)

1. Check gas supply, flow regulator

and gas hoses.

2. Check gun connection to

machine for obstruction or leaky
seals.

RECOMMENDED
COURSE OF ACTION

Contact your local Lincoln
Authorized Field Service Facility.

GAS FLOW PROBLEMS

SP-135 PLUS