A-1

INSTALLATION

SP-125 PLUS

Fuse or

Output Mode

Input Voltage

Breaker Size

Input Amps

Extension Cord

RATED

115V/60Hz

20 Amp

20

Three Conductor

#14 AWG

(2.1 mm

2

) or Larger

for up to

MAXIMUM

115V/60Hz

25 Amp

25

25 feet (7.6m)

Three Conductor

#12 AWG

CSA

115V/60Hz

15 Amp

15

(3.3 mm

2

) or Larger

for up to

50 feet (15.2 m)

TECHNICAL SPECIFICATIONS – SP-125 Plus

INPUT – SINGLE PHASE ONLY

RATED OUTPUT

OUTPUT

RECOMMENDED INPUT CABLE AND FUSE SIZES

Height

Width

Depth

Weight

12.0 in

9.75 in

16.5 in

54 Ibs

305 mm

248 mm

419 mm

24.3 kg

PHYSICAL DIMENSIONS

Standard Voltage/Frequency

Input Current

115V/60Hz

20 Amps - Rated Output

115V/60Hz

25 Amps - Maximum Output

115V/60Hz

15 Amps - CSA Rated output

Duty Cycle

Amps

Volts at Rated Amperes

20% Duty Cycle – Rated DC Output

90

18

20% Duty Cycle - CSA Rated Output

63

20

Welding Current Range (Continuous)

Maximum Open Circuit Voltage

Auxiliary Power

Rated DC Output: 0 - 90 amps

28

N/A

CSA Rated DC Output: 0 - 63 amps

Useable Amperage Range

25 – 125 Amps

.