Troubleshooting, Caution – Lincoln Electric IM968 SAE-500 SEVERE DUTY User Manual

Page 24

background image

E-2

TROUBLESHOOTING

E-2

SAE-500™ SEVERE DUTY™

Observe all Safety Guidelines detailed throughout this manual

If for any reason you do not understand the test procedures or are unable to perform the tests/repairs safely, contact your
Local Lincoln Authorized Field Service Facility for technical troubleshooting assistance before you proceed.

CAUTION

PROBLEMS

(SYMPTOMS)

POSSIBLE

CAUSE

RECOMMENDED

COURSE OF ACTION

Engine will “crank” but not start.

Machine fails to hold the “heat”
constantly.

1. Air intake shut-off is closed.

Manually reset inside machine.

2. Out of fuel. Fill fuel tank.

3. Fuel shut off valve is in off posi-

tion.

4. Low battery voltage.

1. Rough or dirty commutator.

2. Brushes may be worn down to

limit of life.

3. Brush springs may be broken.

4. Field circuit may have variable

resistance connections or intermit-
tent open circuit, due to loose con-
nections or broken wire.

5. Electrode or work lead connec-

tions may be poor.

6. Wrong grade of brushes may be

installed on generator.

7. Field rheostat may be making

poor contact and overheating.

8. “Current Control” may not be

operating properly.

9. “Current Control” brushholder con-

tact springs may be worn out or
missing. Contact surface may be
dirty, rough and pitted.

10. “Current Control” brushholder

support stud and mating contact
surfaces may be dirty or pitted
and burned.

11. Engine running at varying

speeds.

If all recommended possible areas
of misadjustment have been
checked and the problem persists,
Contact your local Lincoln
Authorized Field Service Facility.