OPERATION

B-6

ZR-10

Load From
115V/230V
Dual Voltage Each Half of

Total From

Receptacle Each 115V

Both 115V

Duplex

Duplexes

0

15

40*

2.2 KW

15

40*

4.5 KW 15

40*

6.7 KW 15

20*

9.0 KW

0

0

TABLE II Maximum Current Draw from 115V GFCI
Duplex Receptacles - No Welding

*Maximum current draw from each 115V
GFCI Duplex is 20 amps

TABLE lll

ELECTRICAL DEVICES USE WITH THE ZR-10

Type

Common Electrical Devices

Possible Concerns

Resistive

Heaters, toasters, incandescent

NONE

light bulbs, electric range, hot
pan, skillet, coffee maker.

Capacitive

TV sets, radios, microwaves,

Voltage spikes or high voltage

appliances with electrical control.

regulation can cause the capac-
itative elements to fail. Surge
protection, transient protection,
and additional loading is recom-
mended for 100% fail-safe
operation. DO NOT RUN
THESE DEVICES WITHOUT
ADDITIONAL RESISTIVE TYPE
LOADS.

Inductive

Single-phase induction motors,

These devices require large

drills, well pumps, grinders, small

current inrush for starting.

refrigerators, weed and hedge

Some synchronous motors may

trimmers

be frequency sensitive to attain
maximum output torque, but
they SHOULD BE SAFE from
any frequency induced failures.

Capacitive/Inductive

Computers, high resolution TV sets,

An inductive type line condition-

complicated electrical equipment.

er along with transient and
surge protection is required,
and liabilities still exist. DO
NOT USE THESE DEVICES
WITH A ZR-10.

The Lincoln Electric Company is not responsible for any damage to electrical components improperly connect-
ed to the ZR-10

Load From
115V/230V
Dual Voltage Each Half of

Total From

Receptacle Each 115V

Both 115V

Duplex

Duplexes

0 15*

60

2.2 KW

15*

60

4.5 KW

15*

40

6.7 KW

15*

20

9.0 KW

0

0

TABLE I Maximum Current Draw from 115V Duplex Receptacles - No Welding

*NEMA 5-15P Plug required for 15Amp Draw