MAINTENANCE

D-1

LN-25 PRO EXTREME

ELECTRIC SHOCK can kill.

• Do not operate with covers

removed.

• Turn off power source before

installing or servicing.

• Do not touch electrically hot

parts.

• Turn the input power to the welding power

source off at the fuse box before working in the
terminal strip.

• Only qualified personnel should install, use or

service this equipment.

----------------------------------------------------------------------

WARNING

SAFETY PRECAUTIONS

ROUTINE MAINTENANCE

• Check weld cables, control cables and gas hoses

for cuts.

• Clean and tighten all weld terminals.

PERIODIC MAINTENANCE

• Clean drive rolls and inner wire guide and replace if

worn.

• Blow out or vacuum the inside of the feeder.

CALIBRATION SPECIFICATION

The voltmeter and flow meter are not calibrated and
are for reference purposes only.

Voltmeter Validation, Across the Arc Analog Meter
Models

Tools required:

• DC voltmeter reference standard
• Constant voltage DC welding power source with

adjustable no-load voltage (DC-400, V-350, CV-400
or equivalent).

To verify the analog voltmeter accuracy:

1. Turn power OFF.

2. Connect the LN25 PRO EXTREME to the constant

voltage DC welding power source. The work lead
of the LN25 PRO EXTREME must be connected to
the work terminal of the power source.

3. Connect the reference voltmeter between the

brass block of the LN25 PRO EXTREME and the
work lead.

4. Turn power ON.

5. Energize the output circuit of the power source.

Adjust the power source output to 20±1 VDC as
measured on the reference meter.

6. Verify that LN25 PRO EXTREME voltmeter reads

between 19 and 21 volts.

If the voltmeter reading is out of range, check for
loose connections or replace the voltmeter. There is
no calibration adjustment for the LN25 PRO
EXTREME voltmeter.