GX 300
1. Output rating in watts is equivalent to volt-amperes at unity power factor. Output voltage is within ± 10% at all loads up to
rated capacity. When welding, available auxiliary power will be reduced.
A-1
INSTALLATION
A-1
TECHNICAL SPECIFICATIONS - GX300 (K2284-1)
Make/Model
Description
Speed (RPM)
Displacement
Starting
Capacities
cu. in. (cu. cm.)
System
2 cylinder High Idle 3700
41(674)
12VDC Battery &
Fuel: 12 gal.
Kohler CH22
Starter 45.4 L
(K2284-1)
22 HP @
Bore x Stroke inch (mm) (Group 58; 435
Oil: 2.0 Qts
3600 RPM Full Load 3500
cold crank amps) 1.9 L
Gasoline
3.03 x 2.85 (77 x 72)
Battery Charger
Engine
INPUT - GASOLINE ENGINE
RATED OUTPUT @ 104° F (40° C) - WELDER
HEIGHT WIDTH
DEPTH
WEIGHT
30.00** in. 21.50 in 42.25 in.
762.0 mm
546.0 mm
1073.0 mm
LUBRICATION
VALVE LIFTERS
FUEL SYSTEM
GOVERNOR
Full Pressure
Hydraulic
Mechanical Fuel Pump
Mechanical Governor
with Full Flow Filter
5% Regulation
AIR CLEANER
ENGINE IDLER
MUFFLER
ENGINE PROTECTION
Low noise Muffler: Top outlet Shutdown on low oil
Duel Element
Automatic Idler
can be rotated. Made from pressure.
long life, aluminized steel.
ENGINE WARRANTY: 2 year unlimited hours (See engine manufacturer warranty for details.)Kohler
Welding Output
Volts at Rated Amps Duty Cycle Max. OCV @ 3700 RPM
CC STICK DC Output
29 Volts @ 305 Amps
100%
CC STICK Output Range
20 to 305 Amps -------
PIPE DC Output
29 Volts @ 300 Amps 100%
PIPE Output Range
40 to 300 Amps -------
Touch Start™ TIG Output Range
30 to 250 Amps 100% 60 Volts
Touch Start™ TIG Output Range
20 to 250 Amps -------
CV WIRE DC Output 29 Volts @ 300 Amps 100%
CV WIRE Output Range 14 to 29 volts -------
Auxiliary Power
1
10,000 Watts Peak, 9500 Watts Continuous, 60 Hz
120/240 Volts
PHYSICAL DIMENSIONS
ENGINE COMPONENTS
RATED OUTPUT @ 104° F (40° C)
.
- GENERATOR
510 lbs. (231kg.)