OIL
The DX500e (CE) is shipped with the engine crankcase filled with
high quality SAE 10W-30 Oil that meets classification CG-4 or CH-4
for diesel engines. Check the oil level before starting the engine. If
it is not up to the full mark on the dip stick, add oil as required.
Check the oil level every four hours of running time during the first
50 running hours. Refer to the engine Operatorʼs Manual for specific
oil recommendations and break-in information. The oil change inter-
val is dependent on the quality of the oil and the operating environ-
ment. Refer to the Engine Operatorʼs Manual for more details on the
proper service and maintenance intervals.
FUEL
DIESEL FUEL ONLY-Low sulphur fuel or ultra low sulphur
fuel in U.S.A. and Canada.
• Fill the fuel tank with clean, fresh fuel. The capacity of the
tank is 20 gals. (75.7L). When the fuel gauge reads empty the
tank contains approximately 2 gals. (7.6ltrs.) of reserve fuel.
NOTE: A fuel shut off valve is located on the pre-filter/sedi-
ment filter. Which should be in the closed position
when the welder is not used for extended periods of
time.
------------------------------------------------------------------------
ENGINE COOLING SYSTEM
Air to cool the engine is drawn in the side and exhausted
through radiator & case back. It is important that the intake and
exhaust air is not restricted. Allow a minimum clearance of 1ft.
(0.6m) from the case back and 16 in. (406mm) from either side
of the base to a vertical surface.
------------------------------------------------------------------------
BATTERY CONNECTION
Use caution as the electrolyte is a strong acid that can burn
skin and damage eyes.
------------------------------------------------------------------------
The DX500e (CE) is shipped with the negative battery cable discon-
nected. Make certain that the RUN-STOP switch is in the STOP
position. Remove the two screws from the battery tray using a
screwdriver or a 3/8"(10mm) socket. Attach the negative battery
cable to the negative battery terminal and tighten using a
1/2"(13mm) socket or wrench.
NOTE: This machine is furnished with a wet charged battery; if
unused for several months, the battery may require a booster
charge. Be careful to charge the battery with the correct polarity.
(See Battery in “Maintenance Section”)
A-5
INSTALLATION
DX500e (CE) (RED-D-ARC)
A-5
MUFFLER OUTLET PIPE
Using the clamp provided secure the outlet pipe to the outlet tube
with the pipe positioned such that it will direct the exhaust in the
desired direction. Tighten using a 9/16"(14mm) socket or wrench.
SPARK ARRESTER
Some federal, state or local laws may require that gasoline or diesel
engines be equipped with exhaust spark arresters when they are
operated in certain locations where unarrested sparks may present
a fire hazard. The standard muffler included with this welder does
not qualify as a spark arrester. When required by local regulations,
a suitable spark arrester, such as the K903-1 must be installed and
properly maintained.
An incorrect spark arrestor may lead to damage to the engine
or adversely affect performance.
------------------------------------------------------------------------
REMOTE CONTROL
The DX500e (CE) is equipped with a 6-pin and a 14-pin connector.
The 6-pin connector is for connecting the K857 or K857-1 Remote
Control or for TIG welding, the K870 foot Amptrol or the K936-3
hand Amptrol. When in the CC-STICK, ARC GOUGING or CV-
WIRE modes and when a remote control is connected to the 6-pin
Connector, the auto-sensing circuit automatically switches the OUT-
PUT control from control at the welder to remote control.
When in the DOWNHILL PIPE mode and when REMOTE CON-
TROL is connected to the 6-Pin or 14-Pin Connector, the OUTPUT
CONTROL is used to set the maximum current range of the OUT-
PUT CONTROL of the REMOTE.
Example: When the OUTPUT CONTROL on the welder is set to
200 amps the current range on the REMOTE CONTROL will be 40-
200 amps rather than the full 40-300 amps. Any current range that
is less than the full range provides finer current resolution for more
fine tuning of the output.
When in TOUCH START TIG mode and when a Amptrol is connect-
ed to the 6-Pin Connector, the OUTPUT dial is used to set the maxi-
mum current range of the CURRENT CONTROL of the Amptrol.
The 14-pin connector is used to directly connect a wire feeder con-
trol cable. In the CV-WIRE mode, when the control cable is con-
nected to the 14-pin connector, the auto-sensing circuit automatical-
ly makes the Output Control inactive and the wire feeder voltage
control active.
NOTE: When a wire feeder with a built in welding voltage con-
trol is connected to the 14-pin connector, do not connect any-
thing to the 6-pin connector.
------------------------------------------------------------------------