Installation, Caution, Warning – Lincoln Electric IM856 RANGER GTX User Manual
Page 11
A-4
INSTALLATION
RANGER GXT
A-4
WELDING OUTPUT CABLES
With the engine off, connect the electrode and work
cables to the studs provided. These connections
should be checked periodically and tightened if neces-
sary. Loose connections will result in overheating of
the output studs.
When welding at a considerable distance from the
welder, be sure you use ample size welding cables.
Listed below are copper cable sizes recommended for
the rated current and duty cycle. Lengths stipulated
are the distance from the welder to work and back to
the welder again. Cable sizes are increased for
greater lengths primarily for the purpose of minimizing
cable voltage drop.
ANGLE OF OPERATION
Internal combustion engines are designed to run in a
level condition which is where the optimum perfor-
mance is achieved. The maximum angle of operation
for the engine is 15 degrees from horizontal in any
direction. If the engine is to be operated at an angle,
provisions must be made for checking and maintain-
ing the oil at the normal (FULL) oil capacity in the
crankcase in a level condition.
When operating at an angle, the effective fuel capacity
will be slightly less than the specified 12 Gal. (45 L).
LIFTING
The RANGER GXT weighs approximately
685lbs.(411kg) with a full tank of gasoline. A lift bail is
mounted to the machine and should always be used
when lifting the machine.
ADDITIONAL SAFETY PRECAUTIONS
HIGH ALTITUDE OPERATION
If the RANGER GXT will be consistently operated at
altitudes above 5000 ft(1524m), a carburetor jet
designed for high altitudes should be installed. This
will result in better fuel economy, cleaner exhaust, and
longer spark plug life. It will not give increased power
which is decreased at higher altitudes. Engine horse-
power is reduced by 3.5% per 1000 ft.(305m) for alti-
tudes above 377 ft.(115m).
Do not operate a RANGER GXT with a high alti-
tude jet installed at altitudes below 5000 ft.
(1524m). This will result in the engine running too
lean and result in higher engine operating temper-
atures which can shorten engine life.
-----------------------------------------------------------------------
Contact your local Kohler Authorized Dealer for high
altitude jet kits that are available from the engine man-
ufacturer.
MUFFLER OUTLET PIPE
Using the clamp provided secure the outlet pipe to the
outlet tube with the pipe positioned such that it will
direct the exhaust in the desired direction. Tighten
using a 9/16” socket or wrench.
CAUTION
• Lift only with equipment of
adequate lifting capacity.
• Be sure machine is stable
when lifting.
• Do not lift this machine using
lift bail if it is equipped with a
heavy accessory such as trail-
er or gas cylinder.
FALLING
• Do not lift machine if lift bail is
EQUIPMENT can damaged.
cause injury. • Do not operate machine while
suspended from lift bail.
------------------------------------------------------------------------
WARNING
TOTAL COMBINED LENGTH OF
ELECTRODE AND WORK CABLES
0-100 Ft. (0-31m)
100-150 Ft. (31-46m)
150-200 Ft. (46-61m)
250 Amps
100% Duty Cycle
1 AWG
1 AWG
1/0 AWG