E-2

TROUBLESHOOTING

E-2

PRO-CUT 20

Observe all Safety Guidelines detailed throughout this manual

If for any reason you do not understand the test procedures or are unable to perform the tests/repairs safely, contact your
Local Lincoln Authorized Field Service Facility for technical troubleshooting assistance before you proceed.

CAUTION

PROBLEMS

(SYMPTOMS)

POSSIBLE AREAS OF

MISADJUSTMENTS(S)

RECOMMENDED

COURSE OF ACTION

No Status indicators light and the fan
does not operate 5 seconds after the
power switch is turned on.

No Status indicators light 5 seconds
after the power switch is turned on,
but the fan operates.

The safety light does not go out.

1. Check the input power to be sure

it is on.

2. Check the power line fuses and

machine connection.

3. Disconnect input power at fuse

panel and check line switch conti-
nuity. Replace line switch if bad.

4. Check the fuses on the input

board.

1. Disconnect input power from the

machine. Check that connectors
on harness between Control Bd.
and Power Bd. are properly seat-
ed.

2. Possible faulty Control Board.

3. Possible faulty Power Board.

1. Check consumables - The safety

light lights when an unsafe condi-
tion exists either at the torch or
somewhere else within the sys-
tem.

2. Possible faulty Power board.

3. Possible faulty Control board.

If all recommended possible areas of
misadjustment have been checked
and the problem persists, Contact
your local Lincoln Authorized
Field Service Facility.