Installation, Warning – Lincoln Electric IM877 POWER WAVE SYSTEM INTERFACE User Manual
Page 10

A-1
INSTALLATION
POWER WAVE
®
SYSTEM INTERFACE
A-1
INSTALLATION INSTRUCTIONS
ELECTRIC SHOCK can kill.
• DISCONNECT INPUT POWER
BEFORE SERVICING.
• DO NOT OPERATE WITH COVERS
REMOVE.
• DO NOT TOUCH ELECTRICALLY LIVE PARTS.
• ONLY QUALIFIED PERSONS SHOULD INSTALL,
USE OR SERVICE THIS EQUIPMENT.
-----------------------------------------------------------------------
1. Disconnect the input power from all components in
the system prior to installation.
2. Refer to the Connection Diagram at the end of this
document for basic installation. Additional informa-
tion can be found in the Power Wave AC/DC 1000
Instruction Manual and Training Literature.
3. The DeviceNet Module in the Power Wave System
Interface is factory configured with a Baud Rate of
125K and the Mac ID of 62. Refer to the DIP switch
setting section of this instruction sheet for special
applications and other configuration information.
4. When installation is complete, re-apply power and
verify the appropriate status lights on all system
components are solid green.
INTERNAL CONTROLS DESCRIPTION
WARNING
TABLE A.1
OBJECT INSTANCE
switch 2 switch 1 Instance
off
off
0
off
on
1(default)
on
off
2
on
on
3
TABLE A.2
Switch 1
Switch 2
Baud Rate
off
off
125K (default)
on
off
250K
off
on
500K
on
on
Programmable value
DeviceNet Baud Rate:
Description
DeviceNet Baud Rate
see Table A.2
Switch
1
2
Switch
Description
1
Object Instance LSB* (see table A.1)(default ON)
2
Object Instance MSB** (see table A.1)(default OFF)
3
Equipment Group 1 Select (default OFF)
4
Equipment Group 2 Select (default OFF)
5
Equipment Group 3 Select (default OFF)
6
Equipment Group 4 Select (default OFF)
7
Reserved for future use (default OFF)
8
Reserved for future use (default OFF)
BANK (S1)
BANK (S2)
1 2 3 4 5 6 7 8
O
N
'BANK S1 DEFAULT'
1 2 3 4 5 6 7 8
O
N
'BANK S4'
DEFINES INTERFACE OPERATION
1 2 3 4 5 6 7 8
O
N
'BANK S2 DEFAULT'
1 2 3 4 5 6 7 8
O
N
'BANK S3'
DEFINES I/O TERMINATION
DIP SWITCH SETTINGS
*LSB - Least Significant Bit
**MSB - Most Significant Bit
Description
DeviceNet Mac ID
Default ID=62
(see Table 3)
Switch
3
4
5
6
7
8